Technical Data; General Data - Festo 8131016 Instrucciones De Utilizacion

Estación de carga de robotino 4
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

6 Technical data

6.1 General data

Parameter
Operating voltage
Power consumption
Charging voltage, battery
Charging current, battery
Supply voltage, Robotino
Power supply, Robotino
Mains connection
Fuse
Dimensions
Weight
Housing material
IP protection
Protection class
Overvoltage category
Operating environment:
Pollution degree
Operating height
CE marking in accordance with:
Subject to change
© Festo Didactic 8134684
Value
1 AC 120 V±10%, 60 Hz (order no. 8131016)
1 AC 230 V ±10%, 50/60 Hz (order no. 8131017)
Max. 240 W
10.8 ... 18 V
Max. 6 A, short-circuit proof, overload-proof
24 V
4 A, short-circuit proof, overload-proof
IEC 60320, C13/C14, IEC plug
Micro fuse, 5x20 mm, 5 A/250 V, slow-blow (2 units)
535 x 212 x 152 mm
Approx. 14 kg
Steel, powder-coated
IP20
I, Operation with protective grounding only
CAT II, Operation in building installation only
Use inside building only
2, Dry, non-conductive contamination
Up to 2000 m above NN (sea level)
Low voltage directive
EMC directive
RoHS directive
Robotino 4 Charging Station – Operating instructions