...die Pumpe sehr laut läuft?
Ursache
Keramikhülse nicht oder
falsch eingebaut.
Keramikachse gebrochen.
8. What to do if...
english
Danger!
When working at the fi lter, assure that no water gets into contact with electrical interfaces.
Disconnect the power plug! In case of problems, visit our website www.eheim.de.
...Top part of fi lter can't be closed
Cause
Filter inserts have been
inserted wrongly.
Filter inserts are too full.
Partition not fi tted properly.
Gasket not fi tted properly.
...Top of fi lter leaks
Cause
Closing clips not closed
properly.
Sealing areas or gasket
soiled.
Sealing ring not fi tted,
inserted wrongly or
damaged.
...Primer does not work
Cause
Pre-fi lter fl ap in pre-fi lternot
closed.
Prefi lter is fi lled with water.
Check valve polluted/
defective.
All manuals and user guides at all-guides.com
Behebung
Keramikhülse richtig einbauen, ggf. ersetzen.
Keramikachse erneuern.
Solution
Push fi lter inserts and prefi lter in until they lie fl ush on top of each
other.
Do not overfi ll fi lter inserts. If need be, clean the touching surfaces.
Push partition into the fi lter container until it engages correctly.
Insert correctly into the groove provided in the upper part of the fi lter.
Check for damage and if necessary replace.
Solution
Close all clips properly.
Clean seal areas and spray lightly with EHEIM-silicon grease spray
Order No. 4001000.
Insert sealing ring correctly or renew.
Solution
Check the pre-fi lter fl ap for pollution and, if required, clean it. The
pre-fi lter fl ap must be unobstructed (see chapter 7.3, step 13).
Empty prefi lter and repeat priming. Priming only works when the
prefi lter is empty.
Clean and, if required, replace the check valve (see chapter 7.3).
37