Material - ITT Flygt 4901 Instalación, Servicio Y Mantenimiento

Ocultar thumbs Ver también para Flygt 4901:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
Minimum permitted geodetic*** pump head without calculation.
PUMP VERSION
4901
Type of outlet
Outlet bend
586 68 00
Short outlet
Outlet pipe
558 08 00
4901
Type of outlet
Outlet bend
586 68 00
Short outlet
Outlet pipe
558 08 00
Maximum allowable pump head (For special version only)
The maximum allowable geodetic pump head is
3.5 metres.
The maximum allowable pump operating head (duty
head) is 5.0 metres. (Closed flush valve.)
* If the approved head is lower than indicated in the
table, contact your nearest Flygt representative for a
calculation of the limitations.

MAteRIAL

Description
Material
Flygt
number
Major
Cast iron
0314.
castings
0125.00
Ball
Cast iron
0314.
(Standard
0125.00
version)
Ball
Poly-
0556.
(Special
urethane
9570.50
version)
Ball seat
Stainless
0344.
steel
2324.02
Regulating
Brass
0456.
valve
5170.04
O-rings, inner Nitrile
0516.
membrane,out- Rubber
2637.04
let pipe and
70°
outlet bend
All manuals and user guides at all-guides.com
CP 3085,
CP/DP 3085,
3102 HT
3102 LT**, MT
stAnDARD VeRsIon 556 51 01(Black painted valve body)
(Includes outlet bend 586 68 00)
4.0 metres
4.5 metres
4.0 metres
3.5 metres
4.0 metres
3.0 metres
sPeCIAL VeRsIon 556 51 02 (Blue painted valve body) For CP/DP 3085/3102 only.
(Includes outlet bend 586 68 00 and outlet pipe 558 08 00)
3.4 metres
2.7 metres
2.3 metres
DIn
Bs
AstM
1691
1452
A48-83
GG-25 Grade
No35B
260
1691
1452
A48-83
GG-25 Grade
No35B
260
W.no
AISI
1.4460
329
CuZn
CZ121 C36000
39Pb3
** -P 3085 performance curves with a shut-off head of
less than 7.0 metres should use the special Version.
*** Difference in height between the water level in the
sump and the highest point of the discharge pipe.
Description
Material
Outer
Nitrile
membrane
rubber
and gasket
40°
Screws,
Stainless
studs,
steel
and nuts
Oil
Rapeseed
oil (0.25 l)
Oil
Mineral oil
(Alternative)
ISO VG 32
(0.25 l)
Surface
Coating
treatment
Two
component.
Installation, Care and Maintenance Flygt 4901, Flush Valve
(en)
CP/DP 3127, 3140,
3152, 3170, 3201,
3300 LT/MT/HT
4.0 metres
3.0 metres
2.5 metres
Flygt
DIn
Bs
AstM
number
0344.
W.no
316
AISI
2343.02
1.4436 S33
316
901762
902933 (black)
902936 (blue)
15