 ADJUSTMENT OF THE DEPTH LIMITERS
Place the depth gauge on the chain (1), so that the depth limiter is protrud-
ing. File the protruding part of the depth limiter with a flat file until the same
level as the depth gauge is achieved. Round the front angle of the depth
limiter.
6.1.6

End of work maintenance

Follow all the maintenance and cleaning instructions in the manual.
Empty the oil tank (18) and close the cap (19).
Remove cutting residues (sawdust) under the rear cover (5). Reassemble and clean the tool perfectly.
Insert the bar cover (20) on the cutting bar.
CAUTION!
Remove the front casing (5) periodically and eliminate any cutting residues which might prevent the tool from
working perfectly.
6.2

Troubleshooting

Type of alarm
No problem
Contact protection
Current sensor error
Damage to MOSFETs
Overcurrent / medium current peak protection
Pruner blocked / motor blocked
Phase loss
Undervoltage / overvoltage
MOSFET overheating
EEPROM error
Phase detection error
Programming error
The motherboard failed to communicate with the bat-
tery pack
6.3

Extraordinary maintenance

CAUTION!
Any extraordinary maintenance work must be performed at a Service Centre authorised by the Manufacturer.
AUTHORISED WORKSHOP
The workshop authorised to carry out repairs on the Manufacturer's products.
Page 50
Number of flashes
Number of beeps
on the display
0
1
2
3
5
6
7
8
9
11
12
13
17
Use and maintenance manual – Instructions
Original instructions Rev.: 00, Date 11/04/2022
Type of error indi-
cated on the dis-
play
0
E00
1
E01
6
E02
6
E03
5
E05
3
E06
4
E07
1
E08
6
E09
6
E11
4
E12
6
E13
10
E17