1.2 Breakdown of delivery components

(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Potencia nominal
Rango de potencia
Average CO concentration at 13% of O
Average NO
concentration at 13% of O
x
Average OGC concentration at 13% of O
Particle concentration at 13% of O
Medium draft
Net weight
Maximum authorized load
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Ø Hot air outlet
Inner fireplace room safety distances (base)
Inner fireplace room safety distances (back)
Inner fireplace room safety distances (sides)
Outer fireplace safety distances (back)
Outer fireplace safety distances (sides)
Outer fireplace safety distances (frontal)
Fireplace room ventilation (entry – exit)
Minimum safety distance to hot air outlets
Average temperature of smoke
Type of combustión
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate number
1. Fireplace's body.
2. Heat-resistant spray paint for touch-ups.
3. Counterweights
4. Bag with: metal clamp, 2x screws, 2x nuts and adhesive rope.
5. Tool for handling registers and opening door.
6. Connector support, air inlet cover and screws.
7. Heat-resistant glove.
8. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
9. Bag with screws and washers.
10. 4x Adjustable foots
11. Cleaning cloth.
12. Air connectors of ᴓ120 mm.
13. Fume exhaust connector.

1.3 Diagram of the equipment's measurements

See the ANNEXED document, section I

2. REQUIREMENTS PRIOR TO INSTALLATION

ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH
UPON INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
(Pa)
(kg/h)
(g/s)
(%)
(kW)
(kW)
3
:
(mg/Nm
)
2
:
(mg/Nm
3
)
2
:
(mg/Nm
3
)
2
:
(mg/Nm
3
)
2
( trial Pa )
(kg)
(fuel - kg)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(cm
2
)
(mm)
(ºC)
Modelo
G 450 DC
11-13
4,05
15,24
82 %
14,8
10-17,5
0,12
91,11
71,88
29,47
12 Pa
232
6
200
550
4000
250
120
120
Se debe aislar
20
20
1300
200
1300
450
250
189
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2019
19/20678-1858-1 | 19/20678-1858-2