Lens
A
Wire Cover
Reconnect the terminal ground wire to the wire
10a
cover. Reattach the wire cover to the fixture.
SUSPENSION MOUNTING
Installing contractor is responsible for determining best installation method for desired location
and selecting the appropriate mounting hardware.
NOTE: UL LISTED: CCN:FKAV/7 TYPE: 1/2 FOR THREADED COUPLER.
recommended
(
)
Drywall
Appropriate hanging
hardware by others
If mounting to drywall: Drill two 1/4in. holes in the ceiling. Fasten the toggle bolt
5b
(not included) into the butterfly nut (not included) before inserting the flaps of the
toggle bolt into the ceiling.
Tighten the toggle bolt and make sure the toggle bolt is secure.
If mounting to wood: Drill two 1/16in. pilot holes in the ceiling.
Fasten the combo wood-machine (not included) end into the hook screw (not
included). Tighten the hook screw and make sure it is secure.
If using the Stem Mounting Kit that is sold separately, see the Stem Mounting
Installation section for installation instructions.
NOTE: Distance between 2 holes is 32.9in.
Appropriate hanging hardware by others
Knock Out
Hole
Wire
Connectors
Installing contractor responsible to supply and secure power
8b
to the luminaire per national or local codes as required via
the fixture's provided wire/conduit knockout access points.
All supporting hardware by others as required.
9b
Make the electrical connections by inserting the wire into
the respective wire connector:
Black wire to black wire.
White wire to white wire.
Green wire to ground wire.
If a 0-10v dimming circuit is available, connect purple
wire to purple wire and gray wire to gray wire.
10b
Reconnect the terminal ground wire to the wire cover.
Reattach the wire cover to the fixture and make sure to tuck
all of the wires inside the wire cover.
Terminal Ground Wire
Close the lens cover.
11a
Wood
A
A
Wire Cover
A
Lens
Appropriate hanging hardware by others
Install the suspension mount cables to appropriate hanging hardware
6b
by others.
7b
Ensure all cable connections and hang points are secure.
End Caps
Lens
Close the lens cover.
11b
Move the locks to the lock position
12b
on both ends of the fixture.
13b
Reattach the end caps.
End Cap
A
Move the locks to the lock position on both ends of
12a
the fixture.
Reattach the end caps.
13a
Restore power to the electrical box. Turn the light
14a
switch on to activate the fixture.
Turn the light switch off and back on again to activate
the direct light only.
Turn the light switch off and back on again to activate
the indirect light only.
NOTE: To change between light modes, the light
switch has to be turned off and on within 3 seconds.
F
G
Restore power to the electrical box. Turn the light
14b
switch on to activate the fixture.
Turn the light switch off and back on again to activate
the direct light only.
Turn the light switch off and back on again to activate
the indirect light only.
NOTE: To change between light modes, the light
switch has to be turned off and on within 3 seconds.