4.6. AC/DC Current Measurement
1) Hold the trigger, open the clamp head and clamp one cable
of the measured circuit.
2) When measured signal >0.2A (AC), the main LCD of the
meter displays the measured current value, the vice LCD
displays current frequency (Note: only when AC current
value >2A could the meter displays its frequency value).
3) When measured signal >0.3A (DC), the main LCD of the
meter display the measured current value.
4.7. DC Voltage Measurement
1) Connect the pen-shaped meter to the measured signal,
when the measured signal >=0.5V, will the meter display
current measuring DC voltage value. When measured signal
is <0.5V, the meter will be default as resistance value,
displays the ohm of the measured signal.
39