4.12. Measure AC current(or DC current) and resistance at
the same time
1) Hold the trigger, open the clamp head and clamp one cable
of the measured circuit, when the measured signal >0.2A
(AC current 0.2A, DC current 0.3A), the meter vice LCD will
display measured current value.
2) Connect the pen-shaped meter to the measured
resistance, when the measured resistance >10MΩ, the
meter will display----, when the measured resistance is less
than 50Ω, the meter buzzer will send out alarm sound.
Operation Guide