CONNECTIONS
12.1
ELECTRICAL CONNECTIONS
ATTENTION
WARNING
SINGLE
PHASE
WIRING
POWER
CABLES
COLORS
ATTENTION
ATTENTION
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
The pump should be installed with the plug connected to a 15 A secondary
branch circuit
IT IS THE INSTALLER'S RESPONSIBILITY TO CARRY OUT THE ELEC-
TRICAL CONNECTIONS IN COMPLIANCE WITH THE RELEVANT STAN-
DARDS.
Comply with the following (not exhaustive) instructions to ensure a proper
electrical connection:
- During installation and maintenance make sure that power supply to the
electric lines has been turned off.
-
Use cables with minimum sections, rated voltages and installation type
that are suitable for the characteristics indicated in paragraph "TECHNICAL
DATA" and the installation environment.
The pump is equipped with a 5 meter 14AWG cord with American type B plug
Three-pole straight UL / CSA 125V / 15A
GREEN CABLE
BLACK CABLE
WHITE/GREY CABLE
The pump should be installed with an electric panel guaranteeing the follow-
ing functions: overload protection, short circuit protection, dry run protection.
DO NOT MODIFY AND / OR MAINTAIN THE CONFIGURATION OF THE
ELECTRICAL PARTS.
TAMPERING OF THE ELECTRICAL PARTS CAN CAUSE
UNEXPECTED ALTERATIONS IN ELECTROMAGNETIC EMISSIONS.
The pump must be installed with an electrical panel that guarantees the fol-
lowing functions:
- overload protection;
- short-circuit protection;
- dry running protection.
During installation and periodically, provide for verification of the ground-
ing circuit in compliance with current regulations.
SUBMERSIBLE PUMP
LINE
NEUTRAL
13
13 /52
/124