User manual
1
U
I
Analyse
Charge
Stage 1: Analysis
Battery condition analysis (level of charge and reversal
polarity, wrong battery connected, etc).
Stage 2: Charging
Fast charging at maximum current up to U1.
(e.g. 13.8 V in
).
Stage 3: Absorption
Charging at a constant voltage U1 (eg: 13.8 V in
Maximum duration: one hour.
• Abnormal under-voltage protection:
This protective safeguard prevents short circuits or excessive damage to the battery. The charger will automatically stop if the vol-
tage is abnormally low for more than 10 minutes.
START-UP MODE
• General browsing:
1
Scroll through the menu using the turn dial.
2
Press the turn dial to enter a parameter setting.
3
Use the turn dial to change the setting's value.
4
Press the turn dial to confirm the new parameter setting.
• Starting up
To start up the machine, use the turn dial to go to the
1
arrow at the top right of the screen and then press the
turn dial.
Scroll through the two drop-down windows (using the turn
dial), which show:
2
1 - It is possible to start-up the machine.
2 - The time remaining to complete the start-up.
Carry out the device's start-up process.
On-screen graphics provide further information about the
start-up process:
3
1 - The start-up process is underway.
2 - The start-up process has been successfully completed.
Translation of the original user manual
2
3
Absorption
).
4
5
Égalisation /
Complément
Equilibrage
Stage 4: Additional information
Gradual voltage increase to U2
). Maximum duration: two hours.
(e.g. 14.4 V in
Stage 5: Equalisation / balancing
Maintaining the U2 voltage (e.g. 14.4V in
Maximum duration: two hours.
Stage 6: Power supply mode
Regulated-voltage application.
1
1
STARTFLASH CNT
6
Mode alimentation
).
2
2
25