1. Operating manual
Before you begin, please read the operating and assembly manual through completely and follow all
the safety instructions and installation instructions. You can find it on our website via the link on the
cover page. This manual is a component of the product. Please store it in an easily accessible place.
When passing the tubular motor on to any future owners, the manual must be passed on as well. Dam-
age resulting from non-compliance with this manual and the safety instructions will void the warranty
(guarantee). We assume no liability for any consequential damage.
2. Hazard symbols
Danger of
fatal electric shock
2.1 Levels of danger and signal words
DANGER! - This hazard will lead to serious
injuries or death if not avoided.
WARNING! - This hazard may result in
serious injuries or death if not avoided.
3. Safety instructions
Risk of fatal electric shock when touching electrical components.
• The electrical connection for the tubular motor and all work on the electrical systems may only be
undertaken by an authorised qualified electrician in accordance with the connection diagrams in the
operating manual.
• Carry out all installation and connection work only in an isolated, de-energised state.
Risk of fatal electric shock when installed incorrectly in damp rooms!
• Observe DIN VDE 0100, parts 701 and 702 in particular, when installing in damp rooms. These regula-
tions contain mandatory protective measures.
The use of defective devices can lead to personal injury and damage to property
(electric shocks, short circuiting).
• Never use defective or damaged devices.
• Check the drive and mains cable beforehand for damage.
• Should you discover damage to the device, please consult our customer service.
According to DIN EN 13659, it is necessary to determine that the movement conditions for the
shutters are maintained in accordance with EN 12045.
• The displacement must be of at least 40 mm on the lower edge in the rolled-out position with a force
of 150 N in the upwards direction.
• It is important to ensure that the extending speed of the shutters for the final 0.4 m is less than
0.15 m/s.
A_VBD_100-007-1_RolloTube_105x148_8x_1c_220204.indd 10
Danger area /
dangerous situation
CAUTION! - This hazard may result in minor
or moderate injuries if not avoided.
ATTENTION! - This hazard may lead to
property damage.