EN
ATTENTION! – For motors in self-learning mode:
The roller shutter may run into the roller shutter box in self-learning mode and be damaged
without stoppers or an end rail.
• Always fit two stoppers or an end-rail to the roller shutter.
• Never dismantle the mechanical stoppers or the end rail from the final roller shutter slat.
WARNING!
Risk of short circuiting resulting from water in the event of improper cabling.
• Never lay the motor cable vertically upwards otherwise water may collect on the cable and run into
the motor, possibly leading to damage.
• Lay the cable in a loop. The loop will cause any water on the cable to collect at the lowest point, from
where it can drain off.
ATTENTION! - Wrongly selected lengths may lead to malfunctions. *
* Follow the information provided in the assembly manual for shaft connectors
9. Safety instructions for the electrical connection
DANGER!
Risk of fatal electric shock when touching electrical components.
• Carry out all installation and connection work only in a de-energised state.
• Disconnect all phases of the mains power lead and secure it to prevent any reconnection.
• Check that the system is de-energised.
Fixed-installation devices...
... must be equipped on the installation side with a circuit breaker for each phase in accordance with
DIN VDE 0700. Switches with a contact opening width of min. 3 mm can be used as circuit breakers
(e.g. a power switch, power circuit breaker or residual-current-operated circuit breaker).
WARNING!
Risk of short circuiting resulting from damaged cables.
• Lay all cables in the roller shutter box so that they cannot be damaged by moving machinery.
• The mains connection for the drive may only be connected with the same conduction type. Consult
customer services if necessary.
A_VBD_100-007-1_RolloTube_105x148_8x_1c_220204.indd 15
15
EN
04.02.22 11:43