Descargar Imprimir esta página

Commissioning - Fine Tuning; Running Direction; Lubrification System And Oil Regulation; Automatic Lubrication - battioni Pagani FAN 420 Manual De Instrucciones De Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 113
Setting the pace since 1953

5.1 - RUNNING DIRECTION

Before starting the Rotary blades vacuum pump make sure that the P.T.O. shaft turns freely and that the direction
of rotation is the same as the one indicated by the arrow.
Never turn the rotary blades vacuum pump in the direction of rotation opposite to the one for which it has been
prepared (indicated by the arrow) as this could damage some components as well as prevent the operation of
the pump
.

6 - LUBRIFICATION SYSTEM AND OIL REGULATION

6.1 - AUTOMATIC LUBRICATION

With this system lubrication occurs in both the intake phase and the compression phase by means of a piston
metering pump with adjustable fl ow rate placed at the back and actuated by the rotor. The oil is injected directly
into the Rotary blades vacuum pump, eliminating manual adjustment and saving a considerable amount of oil.
Automatic lubrication is provided as standard on the FAN pumps

6.2 - OIL TO BE USED

The rotary blades vacuum pumps are supplied WITHOUT lubrication oil
in the tank. Battioni Pagani® RECOMMENDS the use of Battioni Pagani
"VACUUM PUMP OIL" for internal lubrication, that ensures
- Excellent resistance to oxidation
- Strong anti-rust property
- Excellent anti foam power
- Working temperature from -5 °C to 160 °C
WITHOUT VACUUM PUMP OIL USE ONLY
new mineral oil ISO VG 100 (SAE 30)

5 - COMMISSIONING - FINE TUNING

Figure 4
.
Automatic lubrication
Figure 5
page 35

Publicidad

loading