2.2 Display
3 ½ digit, 15mm LCD display
2.3 Hold Button
Press to keep the current reading on the display.
•
Press the button again to return to normal display.
•
2.4 Rotary Switch
The rotary switch is used to switch between functions/
ranges.Functions are: voltage, current, resistance, diode,
continuity and transistor gain.
2.5 Input Jacks
VΩmA°C°F
:voltage
•
,
continuity measurement input
COM: Common lead input
•
10A: Greater than 200mA current measurement input
•
red test lead
(
)
2.6 Automatic Power Off
After 15 min. of non-use the meter will automatically turn
itself off.To turn the meter back on, move the rotary
switch to any position except off.
2.7 Accessoies
Manual
•
Test Leads
•
Case
•
Type-K Thermocouple
•
9V Battery
•
resistance
mA current
diode
,
,
red test lead
(
)
black test lead
(
)
1piece
1pair
1piece
1piece
1piece
05
3. Specifications
3.1 General Specifications
Function
Safety Rating
Pollution degree
Operating Altitude
Operating Temperature/
Humidity
,
Storage Temperature/
Humidity
Temperature
coefficient
Max. Input between
terminals and earth
ground
Fuse Protection
Sample Rate
Display
Over-range Indication display shows"1"
Low Battery Indication
Polarity Indication
Power
Dimensions
Weight
Range
600V CAT III
2
<2000m
0~40°C, (<80% RH)
-10~60°C, (<70% RH, remove battery)
0.1xaccuracy/0°C (<18°C or >28°C)
600V DC or AC rms
F1 400mA/600V
F2 10A/600V
Approx. 3 times/sec,
3 ½ digit LCD display,max. reading: 1999.
When battery voltage drops below the
normal operating voltage,"
appear on the display.
Display automatically displays "-"
9V battery NEDA 1604 or 6F22
158(L)x74(W)x36(H) mm.
approx. 220g (including battery)
06
"will