Descargar Imprimir esta página

Important; Electricity Supply - Lavorwash RIO-R Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
· Connect a supply hose (not included) to the water
inlet of the unit and to the water supply.
· Open the water supply.
WARNING: (symbol) machine not suitable for
connection to the potable water mains.
The cleaner can only be connected to the wa-
ter mains if the water mains is separated by a
backflow preventer. Make sure that the hose
is at least Ø 13mm-1/2 inch and that it is rein-
forced.
W ARNING: Water that has flown through
backflow preventers is considered to be
nonpotable.
IMPORTANT: Only clean or filtered water
should be used for intake. The delivery of
the water intake tap should be equal to the
double of the maximum pump range.
- Minimum delivery rate: 15 l/ min.
- Maximum intake water temperature: 40°C
- Max inlet water pressure: 1Mpa
Place the cleaner as close to the water supply
system as possible.
Water supply from an open container
· Unscrew the coupling part for the water inlet.
· Screw the suction hose with filter (not included)
onto the water connection of the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the high-pressure
outlet of the unit.
· Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
· Switch off the unit and screw on the high-pressure
hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
> ELECTRICITY SUPPLY
- The appliance's electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT: Before connecting the ap-
pliance, make sure that the nameplate data
are the same as those of the electrical mains
and that the socket is protected by a differ-
ential security breaker with tripping sensitiv-
ity below 0.03 A
- 30 ms.
- If the appliance's
plug is not com-
patible with the
socket, have the
socket replaced
with another of
suitable type by
p r o f e s s i o n a l l y
qualified staff.
- Never use the
appliance in am-
bient
tempera-
tures below 0° C if it is equipped with a PVC
(H VV-F) cable.
• XY WARNING: Inadequate extension cords
can be dangerous.
• XJ WARNING: If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
> PLUG
HOW TO CONNECT THE CORD TO A U.K. PLUG:
IMPORTANT The wires in the mains lead are col-
oured in accordance with the following code:
Blue
Brown
Yellow/Green
Please read the instructions given below before
connecting the cord to a plug. If in doubt please
consult a qualified electrician. As the colours of the
wires in the mains lead of this appliance may not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows: The
wires that is coloured Brown must be connected to
the terminal which is marked with the letter L or col-
oured Red. The wire that is coloured Blue must be
connected to the terminal wich is marked with the
letter N or coloured Black. Safety points for rewire-
able or moulded plug: The mains lead of this appli-
ance may be already fitted with a BS1363 13A plug.
EN
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
Neutral
Live
Earth
19

Publicidad

loading

Este manual también es adecuado para:

Kappa a-rXtr-rKappa-r