PSS 3100 SE
3.5 Safety devices
The machine is equipped with the following safety devices:
Safety device
Fixed guard
Large contact surfaces for the antiskid guide rails
Feed and saw blade drive are operated from a single
control point
Riving knife/splitter
Hose connector
If the safety devices are damaged or not functioning properly, follow the instructions in the chapter
Troubleshooting. For other malfunctions, please contact your dealer or MAFELL Customer Service directly.
01/2022
Danger
Risk of injury from missing safety devices
These devices are necessary for the safe operation of the machine. They must
not be removed or rendered ineffective.
Check the proper functioning of the safety devices before you start
➢
operating the machine.
Never use the machine with missing or ineffective safety devices.
➢
Type of check
Visual check for damage
Functional check (pushing the saw blade out to full
cutting depth and jerk-free abrupt return to the upper
end position and engaging in this position).
Visual check for damage and deformation
Visual check for damage and deformation
Visual check for damage and deformation
Visual check for damage and obstruction