Installation variants
• Variant (a): Pond bottom filtration only
– With pond bottom filtration only, the water is drawn in only through the filter casing (in-
let 1).
– Set inlet 2 to position "0".
– Close inlet 2 with the cover cap.
• Variant (b): Pond bottom filtration and filtration via satellite filter or skimmer
– For pond bottom filtration, the water is drawn in via the filter casing (inlet 1). Inlet 2 draws in
water via a satellite filter or skimmer.
– Set inlet 2 to position "1", "2" oder "3", depending on the desired flow rate (25/50/75 %).
• Variant (c): Filtration only via satellite filter or skimmer
– Only inlet 2 draws in water via a satellite filter or skimmer.
– Set inlet 2 to position "4".
• Variant (d): Dry installation of the pump
– The pump is installed outside the pond but lower than the water level.
– With this variant, the pump must be installed without a filter casing.
24
AMX0138