about two hours without any water in it, in order to eliminate the humidity accumulated during incubation and
cleaning; in this way, correct operation will be guaranteed the next time it is used.
PRACTICAL INSTRUCTIONS FOR REPLACING THE BULB
To replace the bulb, proceed as follows:
i) Remember to always stop the machine and unplug the power cord from the outlet and let the bulb cool
down to avoid the danger of burns;
j) Using a Phillips screwdriver, unscrew the side and bottom support screws of the guard;
k) Lower the guard by placing it on the bottom of the machine;
l) Unscrew the bulb to be changed in an anti-clockwise direction (be careful with broken bulbs which could
cause cuts or abrasions);
m) Then insert the new bulb, screwing it carefully clockwise;
n) Finally, reposition the protective grille, screwing in the screws correctly.
BEFORE CONTACTING THE ASSISTANCE SERVICE
Before requesting technical assistance, it is advisable to check the following most common faults and intervene
accordingly.