Sensing range adjustment
WLA12Lx-xxxxxx3xAxx with teach-in button:
The sensitivity and operating reserve are optimized by pressing the teach-in button until
the yellow LED flashes (approx. 1-3 seconds). Lead an object into the path of the beam.
The yellow LED goes out, meaning the object is detected and the setting is correct.
1
1...3 sec.
2
Figure 14: WLA12Lx-xxxxxx3xAxx, adjusting the sensing range with teach-in button
NOTE
Do not operate the teach-in button using sharp objects.
Please refer to the enclosed "IO-Link photoelectric sensors" operating instructions for
information about adjusting the IO-Link sensing range.
IO-Link
The sensor can be used in standard I/O mode (SIO) or IO-Link mode (IOL). All auto‐
mation functions and other parameter settings are effective in IO-Link mode and in
standard I/O mode. Output of binary switching signals in standard I/O mode via pin
4 / black wire and via pin 2 / white wire.
Information on the IO-Link functions (IODD) can be found in the enclosed IO-Link
photoelectric sensor operating instructions or downloaded from
the device part number.