Safety
Important Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual
contains important instructions that should be
followed during installation, operation, and
maintenance of the product.
safety alert symbol. When you see this symbol
on your pump or in this manual, look for one
of the following signal words and be alert to the
potential for personal injury!
indicates a hazard which, if not
avoided, will result in death or serious injury.
indicates a hazard which, if not
avoided, could result in death or serious injury.
indicates a hazard which, if not
avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions
in this manual and on pump .
Keep safety labels in good condition. Replace
missing or damaged safety labels.
California Proposition 65 Warning
This product and related
accessories contain chemicals known to the
State of California to cause cancer, birth defects
or other reproductive harm.
Specifications
Power supply required .................................. 115V, 60 HZ.
Liquid Temp. Range ....................... Less Than 120°F (50°C)
Individual Branch Circuit Required (min.) ............15 Amps
Motor Full Load:
CLSU6 (1/4 HP) ....................................................6 Amps
CLU25 (1/3 HP) .................................................10 Amps
Discharge ....................................................... 1-1/4" FNPT
Pump water only with this pump.
Do not use where water recirculates.
Not designed for use as a swimming
pool drainer.
Performance
Model
5' (1 .5m)
CLSU6
1170 (4 429)
CLU25
2100 (7 949)
This is the
GPH (LPH) at Total feet (m) of lift
10' (3m)
15' (4 .6m)
Capacity Gallons(L)/Hour
1020 (3 861)
810 (3 066)
1740 (6 587)
1380 (5 224)
Risk of explosion . Do not
ground to a gas supply line. Do not use in
explosive atmospheres.
NOTICE This unit is not designed as a waterfall
or fountain pump, or for applications involving
salt water or brine! Use with waterfalls,
fountains, salt water or brine will void warranty.
1. Know the pump application, limitations, and
potential hazards.
2. Do not use in water with fish present. If any oil
leaks out of the motor it can kill fish.
3. Disconnect power before servicing.
4. Release all pressure within system before
servicing any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump.
An unsecured discharge line will whip,
possibly causing personal injury and/or
property damage.
7. Check hoses for weak or worn condition
before each use, making certain that all
connections are secure.
8. Periodically inspect the pump and the
system components. Keep free of debris and
foreign objects. Perform routine maintenance
as required.
NOTICE Utility pumps can be submersed for
short-term dewater applications but not used
for permanent installation .
20' (6 .1m)
25' (7 .6m)
510 (1 931)
960 (3 634)
420 (1 590)
No flow at height
shown below
-
25' (7.6m)
28' (8.5m)
2