1. Ensure the machine is on a level and even surface.
2. Ensure both safety release valves have clearance
and are
not obstructed.
3. Ensure the machine is clean and clear of debris.
4. Ensure the heaters are not cracked or broken.
5. Ensure the reflector is free from dust or debris.
6. Ensure that no objects or debris are obstructing the
temperature sensor.
7. Ensure that the seal is clean and even, with minimal
warping and distortion.
See section 6.1 to clarify the above operations.
5.2. What to do in emergency and exceptional
situations
WARNING
Make sure you know where the emergency stop
buttons are located before operating the machine.
To emergency shut down your machine, switch off the
machine at the mains, lower the lid and unlock both
locks. All activities of the machinery are then aborted.
Once ready, the machine can be turned back on with
no reset required.
5.2.1. Emergency situation
In the case of an overheating / fire event:
1. Switch off the machine at the mains and close the
lid immediately (if possible).
2. A CO2 or powder fire extinguisher shall be used due
to electrical components in the machine.
3. Do not attempt to repair the machine, all repairs
shall be carried out by a trained professional.
In the case of an overpressurisation event:
4. Switch off the machine at the mains and allow it to
cool down.
5. To vent the dome, pull down on the ring tab on the
safety release valve, positioned on the base of the
machine (bottom rear, see diagram in section 2.5).
6. To vent the tanks, pull down on the ring tab on the
16
safety release valve, positioned on the base of the
machine (bottom front, see diagram in section 2.5).
6. Maintenance
WARNING
Opening or modifying the machine will void your
warranty and could cause serious injury or death.
6.1. How to maintain the machine
Product maintenance by non-skilled persons

6.1.1. Cleaning and lubrication

(Fig 1.) Cleaning the seal:
1. Use a damp microfiber cloth and clean the seal
in a circular motion, making sure the seal is
seated properly into the dome.
(Fig 2.) Cleaning the mesh:
1. Locate screws.
2. Unscrew.
3. Clean with damp cloth.
(Fig 3.) Cleaning the heat sensor:
1. Use dry compressed air to remove any debris or
obstructions.
2. Use a cotton swab to gently clean the sensor.
(Fig 4.) Lubricating the rails:
1. If the rails are running dry and making a grating
sound, apply a small amount of lithium based
lubricant to the rails. Do not use any type of dry
lubricant (PTFE powder, graphite powder, etc.) with
any recirculating ball or roller type of bearing. While
these lubricants are good for sliding motion, they do
very little to aid rolling friction.
(Fig 5.) Cleaning the heat reflector:
1. Clean the reflector with a microfiber cloth, avoiding
the heaters where necessary.
Mayku Multiplier
Fig1.
Fig3.
Fig5.
Installation and User Instructions
Fig2.
Fig4.

6.1.2. Draining the tank

NOTICE
Draining the tanks creates a loud noise, and can
spray water out the bottom of the machine. Make
sure a thin towel is placed under the machine,
without obstructing the release valve.