1. Preface
1.1. Description of the user
These instructions are intended for the end-user of the
Multiplier. The end-user can be described as each
person who interacts directly with the machinery. The
end-user typically includes, but is not limited to the:
• Operator
• Installer
• Maintenance personnel or technicians
Any maintenance required outside of this user manual
shall be carried out by an authorised, qualified and
skilled maintenance personnel.
1.2. Conventions used in this manual
Bold
• Names of machinery elements, options, processes,
services, and utilities
• Names of interface elements (such as windows,
dialog boxes, buttons, fields, and menus)
Italic
• Publication titles referenced in text
• Emphasis (for example a new term)
• Variables
1.3. Explanation of safety warnings
DANGER
DANGER indicates a hazard with a high level of risk
which, if not avoided, will result in death or serious
injury
WARNING
WARNING indicates a hazard with a medium level
of risk which, if not avoided, could result in death or
serious injury.
CAUTION
CAUTION indicates a hazard with a low level of
risk which, if not avoided, could result in minor or
moderate injury.
6
NOTICE
NOTICE indicates information considered important,
but not hazard-related.
1.4. Retaining instructions
Read and understand this manual and its safety
instructions before using this product. Failure to do so
could result in serious injury or death.
Follow all the instructions. This will avoid fire, explosions,
electric shocks or other hazards that may result in
damage to property and/or severe or fatal injuries.
Keep all safety information and instructions for future
reference and pass them on to subsequent users of
the product.
The manufacturer is not liable for cases of material
damage or personal injury caused by incorrect
handling or non-compliance with the safety
instructions. In such cases, the warranty will be voided.
1.5. Obtaining documentation and information
The latest version of the documentation and additional
language translations are available at:
mayku.me/manuals
For other questions, information, technical assistance
or ordering user instructions, please contact the
manufacturer:
Mayku Ltd
The Biscuit Factory, Unit J410
Jam Studios, 100 Drummond Road
London, United Kingdom, SE16 4DG
Website: https://www.mayku.me/
Contact: support@mayku.me
Mayku Multiplier
2. Description of the Mayku Multiplier
2.1. Intended use and reasonably foreseeable misuse
The Multiplier is intended to be used as a desktop
pressure forming machine, manufacturing high detail
molds for a range of applications.
The Multiplier is intended for indoor use in a well
ventilated area only.
Unintended uses:
• The machinery shall only be used for applications
as described by the manufacturer. All other
applications are unprofessional and considered
dangerous. The manufacturer cannot be held liable
for damage resulting from errors, unintended or
unprofessional use of the machinery.
• This machinery is not intended for use by persons
(including unsupervised children) with restricted
physical, sensory or intellectual capability or lack of
experience and/or knowledge.
• Only use the machinery within the specified
performance limits as described in these
instructions.
• An external compressor shall not be connected to
this machine under any circumstances. This may
result in injury or death.
The Multiplier shall only be used in accordance with
the instructions described in this installation and
user manual. Any use other than those described in
these documents is considered as unintended use.
Unintended use will invalidate the warranty.
2.2. System overview
The Multiplier is loaded with sheets of thermoplastic
which are locked into the machine and heated past
their glass transition temperature using an infrared
heating element. Once at the required temperature
the lid is locked, and up to 60 PSI of pressure is
applied into the dome and to the sheet. This pressure
is generated by a compressor which stores air inside
Installation and User Instructions
internal tanks. The pressure is then vented through a
silencer and the sheet is left to cool before removal.
2.3. Technical data
Parameter
Unit
Device name
Mayku Multiplier
Designation
Pressure Former
Type
Thermoforming Machine
Technical life span
10 Years
Input
110-240V, 12A/6A
(Single Phase)
Maximum Pressure
4.1 bar/60 psi (Dome),
12 Bar/175 psi (Tank)
Max Power
1500W
Weight
Unboxed: 59kg (130lbs)
Boxed: 68kg (149lbs)
Frequency band
2.4GHz
Maximum radio-
21dBm
frequency power
transmitted in the
frequency band(s)
in which the radio
equipment operates
7