B E FO R E U S I N G YO U R N E W D E V I C E
1) Remove your NuBODY and power adapter from the box.
2) Place your NuBODY on a counter or table top. Keep away from any source of water.
3) Connect the power adapter to the NuBODY. Plug adapter into the wall outlet to charge your
device. Note: NuBODY cannot be used while plugged into the outlet and will not turn ON
while charging.
4) Important: Charge your NuBODY for approximately 16 hours before the first use. The blue
LED lights will blink, showing that your NuBODY is charging. All 3 blue LED lights will stay lit when
NuBODY is fully charged.
5) Important: Test your skin to make sure you are not sensitive to the NuFACE Microcurrent
Activator. To do so, apply a dime-sized amount of the NuFACE Microcurrent Activator on your
forearm. Leave for 15–30 minutes before washing it off. If an allergic reaction (rash, redness, etc.)
develops, immediately contact NuFACE for recommendations on alternate NuFACE Microcurrent
Activators. You should not initiate treatment with the NuBODY device until your reaction to the
NuFACE Microcurrent Activator has been resolved.
6) When NuBODY is ON it will emit an energizing hum. The default intensity is set at the minimum level.
7) Always ensure that all four [4] of the spheres remain in direct contact with the treatment area.
Always glide upward with medium pressure without pulling or dragging the skin.
8) NuBODY emits a tonal beep every five (5) seconds to indicate when to move to the next position
if desired. This beep will change to two (2) tonal beeps when the battery needs recharging.
Note: NuBODY will NOT contract the muscles. The current is soft, soothing, and mild when
used correctly.
D E V I C E F E E D BAC K
Ascending Beeps
Descending Beeps
Tonal Beep
Dual-Tone Beep
Two series of tonal beeps when device powers OFF indicates the battery requires charging
N U FAC E M I C RO C U R R E N T AC T I VATO R
The essential first step to your microcurrent treatment to ensure optimal results. Important:
Always apply Microcurrent Activator when using the NuBODY Device. Refer to packaging for
use by date.
T R E AT M E N T A R E AS
The NuBODY Device is designed with four treatment spheres designed to stimulate the larger,
denser areas of the body. Follow instructions below for best results and refer to your Quick Start
for more detailed images.
T R E AT M E N T T EC H N I Q U E S
GLIDES :
To glide, place NuBODY at the starting point of a treatment area. When it beeps, slowly glide
the device in an upward motion using medium pressure to the endpoint until the beep sounds
(5 seconds).
HOLDS (Recommended for stubborn areas):
To hold, place NuBODY on the targeted area and hold in place for at least 2-3 beeps
(10-15 seconds). Do not glide. You may treat multiple stubborn areas within the treatment area
for up to 5 minutes.
6
I N D I CAT E S
Powered ON
Powered OFF
Intensity Adjusted
End of Glide Interval