Descargar Imprimir esta página

Entering Welding Parameters Manually; Manually Entering Welding Voltage And Time; Entering The String Of Numbers - HURNER HST 300 Print+ 2.0 Manual De Instrucciones

Ocultar thumbs Ver también para HST 300 Print+ 2.0:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
key in Display 12, "Poor GPS signal; record data?". When
this message is showing, you can still start recording the
position by pressing the START/SET key or go on without
recording by pressing the STOP/RESET key.
The recorded position is the one the GPS module
is at at the moment of recording. This means that
in situations where the welding unit cannot be set
Info
next to the joint that is being welded, it is possible
to start by placing the welder/the GPS module next
to the future joint, then to record the geo-data,
and finally to move the welder to the place where
it will be during the welding process.
7

Entering Welding Parameters Manually

To be able to enter the welding parameters manually, you
have first to connect the fitting to the welding unit with
the welding cable. The manual input of the parameters can
then be accessed by pressing the ò arrow key. The screen
will show a menu as reproduced in Display 14, provided
manual input is enabled in the configuration menu (see
Sect. 10.1). In other words, the manual parameter input
replaces reading the bar code of the fitting with a scanner.
Using the arrow keys ñ and ò you can select "Enter Volt-
age/Time" or "Enter Fitting Code" (i.e., the numbers that
represents the code of the fitting to be used). Confirm your
selection by pressing the START/SET key.
7.1

Manually Entering Welding Voltage and Time

If this option was chosen in the manual parameter input
menu, a display like the one to the right appears on the
screen. Use the alphanumeric keypad (see Info in Sect. 5.2)
to set the welding voltage and the welding time, accord-
ing to the fitting manufacturer's instructions, then press
the START/SET key to confirm your input. The "Start ?"
message displayed after the confirmation by START/SET
indicates that the unit is ready for welding.
7.2

Entering the String of Numbers

If this option was chosen in the manual parameter input
menu, the "Enter Fitting Code" display shows. The 24 char-
acters of the fitting code to be entered display as asterisks
( * ). Use the alphanumeric keypad (see Info in Sect. 5.2) to
enter the code and press START/SET to confirm your input
and have it decoded. If the code entered is not correct, a
"Code Error" message appears; check the string of numbers
Version September 2022
HÜRNER HST 300 Print + 2.0 User's Manual
**
MANUAL INPUT
**
>Enter Voltage/Time
Enter Fitting Code
Display 14
Voltage/Time
U= 40 V
t=
1000 s
Display 15
EN
17

Publicidad

loading