ing the STOP/RESET key.
10 Configuring the Welding Unit
With the operator identity card, the welding unit can be
reconfigured. When the MENU key is pressed, the "Enter
Menu Code" message appears on the screen. After the
code was read from the operator card, the selection menu
in Display 17 shows.
At "Settings," the parameters related to the welding unit
itself and its operation can be set. At "Recording," the
traceability data that have to or need not be recorded
and written into the reports can be enabled or disabled.
The desired sub-menu is selected using the ñ and ò arrow
keys. Then to access that sub-menu, press the MENU key.
In both parts of the configuration menu, use the ñ and
ò arrow keys to select the desired set-up option. Use the
ð arrow key to toggle between "on" and "off" for that
set-up option.
If a "M" is shown next to a set-up option, this indicates that
a sub-menu is accessible here by pressing the MENU key.
Press the START/SET key to confirm the set-up and save it
to memory.
10.1 Understanding the "Settings" Sub-menu
"AutoWeld on" means that the AutoWeld feature for the
easy definition of welding parameters (see Sect. 5.5)
can be used, "off," that the feature is not available.
"Check Code Expiry on" means that the welder identifica-
tion code has to be current and not expired (default
period of validity 2 years from code issuance), or the
welding operation cannot be started, "off," that the
validity of the code is not checked at all.
"Memory Control on" means that when the system
memory is full of reports, the unit will be blocked until
the reports are printed or downloaded, "off," that it
works but that the oldest report will be overwritten.
"Manual Input on" means that the manual input of weld-
ing parameters (see Sect. 7) is possible, "off," that the
manual input is not allowed.
"Welder Code Options – M – " means that by pressing the
MENU key, the user can access a sub-menu that allows
determining when the welder code, if it is enabled at
"Recording," has to be entered:always, i. e. before evey
single welding operation, only before the first welding
22
EN
HÜRNER HST 300 Print + 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
>Settings
Recording
***
SET-UP MENU ***
>AutoWeld
Check Cd Expiry off
Memory Control
***
SET-UP MENU ***
Manual Input
Wldr Code Option-M-
>Language
***
SET-UP MENU ***
Date/Time
Buzzer Volume
>Temp. Unit
Version September 2022
-M-
-M-
Display 17
on
on
Display 18
-M-
-M-
Display 19
-M-
-M-
-M-
Display 20