The generator engine only runs with unleaded petrol 95.
Never use contaminated petrol or other types of fuel. Avoid
the presence of dirt or water in the tank.
To check the fuel level and to fill the tank, the engine must
be stopped.
When filling the fuel tank, do not exceed the
maximum level, the upper limit of the filter.
Remark:
▪ 12V direct current's generator
▪ Start the engine first and only then connect the
generator to the battery;
▪ After starting to charge the battery, make sure the DC
protector is on.
1. Start the engine;
2. Plug the red battery charger cable into the positive
terminal (+);
3. Plug the black battery charger cable into the negative
terminal (-);
4. Switch off the ESC switch to start charging the battery.
▪ Make sure the ESC switch is off while the battery is
charging;
▪ Make sure you connect the cables to the correct
terminals. Never do the opposite;
▪ Make sure to connect the cables firmly to the terminals
so that they do not become disconnected due to engine
vibration or other turbulences;
▪ The DC protector switches off automatically if the current
exceeds normal values during battery charging. To
charge the battery again, switch on the DC protector by
pressing the knob. If the protector shuts off again,
disconnect the battery immediately and consult the
brand or authorized dealer.
When using the generator, verify that the total power is
within the normal rated output voltage of a generator.
Otherwise, damage may occur.
AC
Power
1
factor
Output
≤1.000W
≤800W
rated
power
It is possible to use AC and DC power simultaneously, but
the total power should not exceed the rated power.
Generator rated power
Frequency
Power factor
AC
DC
Overload indictor light comes on when total power
exceeds power range.
▪ Don't overload. The total load of all electrical devices
must not exceed the power range of the generator.
Overloading will damage the generator;
▪ When supplying power to precision equipment,
electronic
controllers, computers,
based equipment or battery chargers, keep the
generator at a sufficient distance to avoid electrical
interference from the engine. Also make sure that
electrical engine noise does not interfere with other
electrical devices located near the generator;
▪ If the generator is going to supply medical equipment,
you should first get advice from the manufacturer,
doctor or hospital CEO;
▪ Some electric equipment or engines for general use have
high inrush currents and therefore cannot be used, even
if they are within the power range limits indicated in the
table above.
0.8-
0.4-0.75
0.95
(Efficiency
0.85)
≤400W
Rated
voltage 12V
1.000W
1.0
≤ 1.000W
0.8
≤ 800W
---------
60W (12V / 5A)
microcomputer-