Descargar Imprimir esta página

Install Blower System - ELICA KIT0179547 Guía De Instalación, Uso Y Mantenimiento

Publicidad

Idiomas disponibles

Idiomas disponibles

1
Determine and mark the vent system exhaust's vertical and
horizontal centerlines on the wal where the kit is going to
be installed.
2 Disconnect the power.
3 Tape the installation template in place, aligning the
template centerlines with the wall marks already made.
TOP BORDER
BORD SUPERIEUR
BORDE SUPERIOR
Ø 10
(Ø 260 mm)
Ø 8
(Ø 210 mm)
A. Intallation template centerlines
B. Upper mounting holes
4 Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the wall, do not
damage electrical wiring or other hidden utilities.
5 Determine the location where the ¹⁄₂" (1.3 cm) wiring
conduit will be routed through the wall between the
external blower and the range hood.
6 Drill a 1¹⁄₄" (3.2 cm) hole at this location.
7 Drill the upper mounting pilot holes using a 3⁄8" (0.95 cm)
drill bit and place the wall anchors.
8 Fix 3 - 6.3 x 60 mm screws to the anchors leaving a ¹⁄₄"
(6.4 mm) gap between the wall and the back of the upper
screws head to slide range hood into place.
9 Remove the template.
10 Place the kit in the desired location and mark with a pencil
the location of the 4 mounting holes.
11 Remove the External Blower Kit.
12 Drill the 4 mounting pilot holes using a 3⁄ 8 " (0.95 cm) drill
bit and place the wall anchors.
A
A. Mounting holes
12
B
/
1
"
Ø
13
/
"
4
16
(Ø 21 mm)
WIRING HOLE
TROU DE CÂBLAGE
ORIFICIO DE CABLEADO
1
/
"
4
A
A
"
1
4
(6.4 mm)
A

Install Blower System

13 Place and attach the external blower motor housing to the
mounting location with mounting 4 - 6.3 x 60 mm screws
and 4 - 4 x 1.8 washers. Parts are included with the range
hood motor kit.
NOTE: The blower motor housing can be mounted using
4 holes from either the inlet side or the outlet side of the
blower.
14 If removed, reinstall the blower motor assembly and secure
it with the screws previously removed.
15 If removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1
Locate the electrical terminal boxes in the external blower
housing and range hood. Remove the terminal box covers
and set the covers and screws aside.
B
2 Remove the electrical knockout from the external blower
housing and range hood (see the range hood installation
instructions) to prepare for the installation of the UL listed
or CSA approved ¹⁄₂" (1.3 cm) wiring conduit and conduit
connector.
3 With the range hood mounted (see the range hood
installation instructions), run the ¹⁄₂" (1.3 cm) wiring conduit
between the external blower motor housing and the
range hood (see the KIT0153054 electrical connection
instructions). Pull enough ¹⁄₂" wiring conduit to allow for
easy connection to the terminal boxes in the external
blower housing and range hood.
NOTE: If necessary remove the range hood transition.
C
A. External Blower Kit
B. Range Hood Terminal Box
C. Power Supply wiring Conduit
C
A
A. Terminal Box Cover
B. Knockout
C. Terminal Box cover screw
E
D
B
D. External Blower Wiring Conduit (not
included)
E. External Blower Terminal Box
F. External Motor Electrical Plug Cable
F