4 Install the conduit connectors and conduit to the external
blower housing and range hood electrical terminal boxes.
NOTE: If removed, install the range hood transition.
5 Connect the vent system to the range hood and external
blower system. Seal all joints with clamps.
6 Once the electrical connection is made, place the kit front
cover with the neoprene washers and the blower mointing
screws.
IWARNING
For the correct use of your product, you must install the
neoprene washers to avoid the water entrance.
Replace the shell cover and fix with the previously removed
10 screws and the additional 5 - 4.2 x 8 mm screws
contained on the hardware bag.

Electrical connection instructions

I WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
I WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box.
Failure to do so can result in death or electrical shock.
NOTE: The electrical diagram is attached at the end of the
document.
Electrical Connection Inside External Blower System
1
Disconnect power.
2 Connect the wires from the wiring conduit to the wires
from the motor electrical plug cable inside the external
blower housing terminal box.
3 Use UL listed wire connectors and connect the black wires
(C) together.
4 Use UL listed wire connectors and connect the white wires
(D) together.
5 Use UL listed wire connectors and connect the red wires
(E) together.
6 Use UL listed wire connectors and connect the blue wires
(F) together.
7 Use UL listed wire connectors and connect the gray wires
(G) together.
8 Connect the green (or green/yellow) ground wire from the
wiring conduit to the green (or yellow/green), ground wire
(H) in the terminal box using UL listed wire connectors.

Electrical Connection for External Blower Motor System

C
D
A. Blower mointing screws
B. Neoprene washers
B
A
A. Strain relief
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
9 Once the connection is done, in necessary to adjust the 6
wire connector with the included strap.
B
A
10 Reinstall the external blower terminal box cover and
screws.
11 Reinstall the front cover of the external blower housing and
secure it with 10 mounting screws.
C. Front cover
D. External Blower
C
D
E
F
G
H
I
F. Blue wires
G. Gray wires
H. Green (or yellow/green) and green/
yellow wires
I. Motor electrical plug cable
D
A. Ground wires connection
B. 6 wire connector
C
C. Strap
D. Strain relief
A
B