• If the product is installed near heat sources: Shield the product.
• Do not install the product close to high-charging processes.
• Compressed air and exhaust are evacuated from the explosive atmosphere
through tubing lines.
Specifications for dust explosion areas
• Ensure that the minimum ignition energy of the dust in the system atmos-
phere is under the following value: 1 mJ.
• Protect the product from dust deposits through a protected installation.
Product-specific requirements
• Mounting orientation. See
g 13. Technical
• Compressed air specifications (material protection). See
• Recommendation: Use oil-free compressed air.
• When using oiled compressed air (not recommended):
– Maximum oil content. See
– Only use oils approved for AVENTICS products.
– Make sure that the oil content of compressed air remains constant during
the service life.
– Never change from oiled to oil-free compressed air.
• Only operate the product with a voltage source and control voltage suitable
for PELV. The voltage source must ensure secure electrical isolation of the op-
erating voltage from the mains in accordance with IEC / EN 60204-1 (accident
prevention).
• Never ground the 24 V side of the supply voltage.
• The product causes high-frequency interference. If there are any sensitive de-
vices in the vicinity of the product, take appropriate interference suppression
measures.
Ambient conditions
• Let the product acclimatize for a few hours before installation. Otherwise wa-
ter may condense in the housing.
• Make sure that the product is protected from the energy of external impacts
to the housing that can occur during operation.
• Keep the installation location free from vibration.
• Protect the product from direct sunlight and UV radiation.
• Make sure that there are no ferromagnetic sources near the product (material
protection).
• Avoid increased output pressure tolerances: Make sure that high-frequency
radiation from interference-emitting devices is kept away from the product.
6.2.2 Required accessories, materials and tools
Select material and tools that are suitable for your product configuration. De-
pending on the configuration, you will need further accessories.
Mounting material
Assembly requires the following material, which is not included in the scope of
delivery. Respect dimensions and tightening torques.
• 2x screws
• 2x seals
• 1x silencer
• 1x screw for ground
• 2x tooth lock washer for ground
Tools
• In explosive atmospheres: Use non-sparking tools.
Accessory parts
• Approved accessories. See g 14. Accessories.
AVENTICS™ Sentronic PLUS 614 | IM14229-R06 | English
data.
g 13. Technical
g 13. Technical
data.
6.3 Preparation
6.3.1 Notes
• If the housing ventilation port is closed, there is no atmospheric equalization
and the characteristic curve will change. Ensure that the housing ventilation
port is open and that the air can circulate freely through the housing ventila-
tion port.
• Make sure that the power supply plug is protected against contamination
with a suitable sealing cap until assembly (material protection).
• Make sure that the pneumatic connections are protected against contamina-
tion with a suitable blanking plug until assembly (material protection).
data.
Specifications for use in explosive atmospheres
• Make sure that the seals are integrated in the plug and not damaged (explo-
sion protection).
• Make sure that all plugs are mounted (explosion protection).
6.3.2 Unpacking and checking the product
1. Check the material number to see if the product matches your order.
2. Check the product for transport and storage damage.
Do not install a damaged product. Return damaged products together with
the delivery documents. See
3. Prepare required accessories, materials and tools.
6.3.3 Implementing safety measures
Procedure
1. Do not carry out any work on the system during preparation.
2. Close off dangerous areas.
3. Make sure the system or system part is not under pressure or voltage.
4. Protect the system against being restarted.
5. Allow the product and adjacent system parts to cool down.
6. Wear PPE.
6.3.4 Software installation
Parameterization software is only required if the default parameterization has to
be changed due to installation in the system. The parameterization software is
available for download in the online catalog.
After parameterization, download and install the product-specific parameteri-
u
zation software if required.
6.4 Installation
6.4.1 Mounting the product
Insert one screw each in the through holes in the housing and tighten. See
u
g 5.4.1 Operating
elements.
Tightening torque: max. 25 Nm
6.4.2 Connecting the pneumatic system
The pneumatic flow direction is from connection 1 to 2.
See
g 5.4.1 Operating
elements.
Procedure
1. Place a suitable sealing ring under each screw connection. Only use imperial
screw connections.
WARNING! Only use connection seals that are not made of teflon or hemp.
2. Connect the supply line to the inlet connection (1).
3. Connect the outlet line to the outlet connection (2).
4. Use a suitable silencer at the exhaust (3).
INFO: Depending on the silencer used, the exhaust time may be longer.
5. Adapt the cross-section of the pneumatic lines to the nominal width of the
valve: The cross-section of the outlet line (2) must be greater than or equal to
that of the inlet line (1).
g 4.3 Returning the
product.