Plug assignment / cable assignment
Pin
Description
1
24 V DC (supply voltage)
1
4
5
2
Analog input (set point)
2
3
3
0 V DC (supply voltage)
4
Analog output (actual value)
5
Digital output (pressure switch)
Hous-
EMC shielding
ing
only with
0 / 4 ... 20 mA
Inductive load
Fig. 4: Electrical connection with 7-pin M16 plug connector

7 Commissioning

7.1 Notes on safety

Danger to life due to dangerous operating states when using serial commu-
nication
If the interface is used, interference from radio waves or other electrical inter-
ference can trigger a reaction. The product no longer responds to the defined
set point value.
Make sure that no interference is present when using the interface.
u

7.2 Basic requirements

Product-specific requirements
• In case of supply pressure interruption: Switch off 24 V supply voltage (mate-
rial protection).
• The PC connection is only intended for maintenance and parameterization
and not for continuous operation. Take precautions against uncontrolled
movement of system parts (accident prevention, material protection).
• Before opening the sealing cap, make sure that the environment is free from
humidity and dust.
AVENTICS™ Sentronic PLUS 614 | IM14229-R06 | English
5-wire cable
6-wire cable
Brown
White
Blue
Black
Gray
Shield
Control
+24 V DC (supply voltage)
0 V DC (supply voltage)
GND
Analog input (set point)
0 ... 10 V
(or 0 / 4 ... 20 mA)
10 V
Set point mass
Not connected
Analog output (actual value)
max. 
0 ... 10 V
500 Ω
(or 0 / 4 ... 20 mA)
Set point mass
Digital output
(pressure switch)
max. 200 mA / 4.8 W
GND
Shield
GND
FE
DANGER
Connection with 7-pin M16 plug
Notes
Brown
• The maximum current at pin 7 is 200 mA (PNP output).
Pin 7 is protected against short-circuits and overloads.
White
Green
• For products with 7-pin M16 connector, the analog ground is routed out on a
separate pin.
Pink
Gray
Procedure
Shield
Connect the product according to the pin assignment.
u
M16 plug, 7-pin.
M16 electrical
connector of the cable
1
2
3
4
5
6
7
Shield
Housing M16 electrical
connector
• IP protection and EMC protection are only ensured if the housing opening for
the PC connection is closed properly. Remove the PC connection cable during
normal operation and close the housing properly with the sealing cap.

7.3 Preparation

Specifications for use in explosive atmospheres
• Make sure that the seals are integrated in the plug and not damaged (explo-
sion protection).
• Make sure that the product is completely closed and undamaged (explosion
protection).

7.4 Step-by-step commissioning

Procedure
1. Switch on the pneumatic supply.
2. Screw in the sealing cap to the stop.
WARNING! Use in explosive atmosphere: Make sure that the sealing cap for
the PC connection is always closed properly (explosion protection).
3. Switch on the 24 V DC supply voltage.
4. Set the pressure. See
5
6
4
M16 flange plug of the
7
valve
3
1
2
250 Ω with
set point 0 / 4 ... 20 mA
Housing M16 flange plug
M4 connection valve housing
g 8.4 Manual pressure adjustment (manual
mode).
20