9.

ERROR CODE LIST

If an abnormality comes up, the induction hob will enter the protective state
automatically and display corresponding protective codes:
Problem
F3/F4
F9/FA
E1/E2
E3
E5
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages to
the induction hob.

10. TECHNICAL SPECIFICATIONS

Model
Type of hob
No. of cooking zones
Heating technologies
Diameter of each cooking zone (Ø)
Energy consumption/ per cooking
zone (E
Celectric cooking
Energy consumption hob (EC
Rated voltage
Rated current
Rated Power
Cord
Dimensions (mm)
Weight and Dimensions are approximate. Because we continually strive to improve our
products we may change specifications and designs without prior notice.

11. INSTALLATION

SELECTION OF INSTALLATION EQUIPMENT

Possible causes
Temperature
sensor
induction coil failure
Temperature sensor of the IGBT
failure.
Abnormal supply voltage
High temperature of the induction
coil temperature sensor
High temperature of the IGBT
temperature sensor
)
electric hob
What to do
of
the
Please contact the supplier.
Please contact the supplier.
Please inspect whether power
supply is normal.
Power on after the power
supply is normal.
Please contact the supplier.
Please restart after the hob
cools down.
UBE2400-20
Built in hob
3
Induction cooking zone
1 = 18 cm 2 = 18 cm 3 = 28 cm
1 = 192,3 Wh/kg
2 = 193,5 Wh/kg
3 = 190,9 Wh/kg
)
192,2 Wh/kg
220 - 240 V~, 50/60 Hz 6500 W
27- 29.5 A
5500 - 6900 W
H07RN-F 5G1.5m
590 x 520 x 55 mm
2