In the context of this manual, the term "sanitizing water" refers to
acidic water and "cleaning water" refers to alkaline water.
IMPORTANT
1. This booklet is an integral and essential part of the product
and should be kept and preserved by the user. Please read
carefully the guidelines and warnings contained herein as
they are intended to provide the user with essential informa-
tion for the continued safe use and maintenance of the prod-
uct. In addition, it provides GUIDANCE ONLY to the user
on the correct services and site location of the electrolyzer.
Please preserve this booklet for any further consultation that
may be necessary.
2. This is a water electrolyzer, and should be destined only
to be used for the purpose for which it has been expressly
designed. Any other use should be considered improper and
therefore dangerous. The manufacturer will not be held liable
or responsible for any damage caused by improper, incorrect
and unreasonable use.
WARNING
1. The installation must be carried out by qualified personnel, in
accordance with current regulations, according to the manu-
facturer's instructions.
2. This electrolyzer is not intended for outdoor use (including
under canopy). Exposure to rain may cause electric leak or
shock. Direct sunlight can damage the plastic tank exterior,
resulting in cracks and water leaks.
3. Ensure adequate ventilation. Hydrogen gas or chlorine gas
may cause health problems.
4. Do not mix electrolyzed water with other chemicals. Mixture
with acidic or chlorine-based chemicals can cause chlorine
gas, resulting in health problems.
5. Do not use a large volume of sanitizing water only. Genera-
tion of a large amount of chlorine gas may cause health
problems or corrosion of surrounding equipment.
Do not use a flame near a container or tank holding electrolyzed
water. Hydrogen gas from cleaning water may cause ignition.
1. CONSTRUCTION
[a] EXTERIOR
[1]
[2]
[3]
[4]
[5]
CAUTION
[8]
[7]
[6]
[1] Operation panel
See "[b] OPERATION PANEL".
[2] Control panel (behind cover)
See "[c] CONTROL PANEL".
[3] Water supply inlet (bottom)
[4] Salt water hose
[5] Filter
[6] Salt water tank
Holds 5 liters of concentrated salt water.
[7] Water outlets (sanitizing, cleaning)
[8] Joints
[9] Dispense sensor
Senses a hand or object to start and stop dispensing electrolyzed wa-
ter without using the dispense button.
[10] Power switch (earth leakage circuit breaker)
Note: To avoid unbalancing the water properties or causing water
leaks, do not block the water outlets.
Do not move the joints. The connections may loosen and cause
water leaks or damage.
[b] OPERATION PANEL
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[1] Operation lamp (green)
Illuminates while the unit is running.
[2] Ready lamp (green)
[9]
Flashes until the desired settings are achieved and stays on while the
unit is ready to dispense proper electrolyzed water.
[3] Add salt water lamp (red)
Illuminates when the salt water tank level is too low. See "10. [a]
OPERATIONAL PROBLEMS".
[4] Replace cell lamp (red)
Flashes when the electrolytic cell needs to be replaced.
[5] Error lamp (red)
Illuminates when any abnormality is detected. See "10. [b] WHEN
ERROR LAMP COMES ON".
[6] Reset button
Press this button after the add salt water lamp comes on. See "3.
PURGING SALT WATER PUMP".
2