3) Turn the power switch back on.
4) Press the dispense button on the operation panel.
5) Check that the add salt water lamp is on.
6) Press the reset button.
7) The pump starts running and pumping up the salt water to purge
the salt water hose. About 90 seconds later, the pump stops.
8) The unit drains water to flush out the electrode before shutting
down. The add salt water lamp goes off.
* Do not press the dispense button on the
operation panel, the power switch or any
other switches before the add salt water
lamp goes off. Otherwise, the lamp cannot
be reset, and the above procedure must be
repeated from step 5). Wait until the unit
flushes out the system and completes the
resetting procedure.
* Always locate the salt water tank below the
end of the water outlets, or the salt water
tank will leak salt water by siphonage and
the unit may fail to operate properly.
4. START UP
1) Plug in the unit.
2) Open the water supply line shut-off valve.
3) Check for proper operation of the water softener. Refer to the
instruction manual provided for operating instructions. See "8.
[f] WATER HARDNESS (WEEKLY)" for how to check for water
softening.
4) Check that the salt water tank is properly set up.
5) Turn on the power switch (earth leakage circuit breaker). A
mechanical sound is heard three times immediately after the power
switch is turned on. This is not a sign of failure.
6) Press the dispense button on the operation panel.
7) The operation lamp comes on.
8) The ready lamp starts flashing, and non-electrolyzed water is
dispensed at first.
9) When the unit starts to dispense electrolyzed water of the intended
quality, the ready lamp stays on continuously.
10) Check that the add salt water lamp is off. If it is on, follow "3.
PURGING SALT WATER PUMP" to supply salt water to the
electrolytic cell until the lamp goes off.
11) To stop dispensing water, press the dispense button on the
operation panel again. The ready lamp goes off. The unit goes
through the flush cycle before water stops.
* While the ready lamp is flashing, the quality of electrolyzed water
has not reached the intended level. If the available chlorine
concentration and pH value are less than the specified values,
sanitizing water may not provide a sufficient bactericidal effect.
* Before using electrolyzed water, check that the ready lamp stays on.
5. SHUT DOWN
1) For daily shutdown, press the dispense button on the operation
panel. The ready lamp flashes for about 3 seconds and the unit
stops dispensing electrolyzed water. To restart the unit, press the
dispense button on the operation panel.
2) For long storage, see "9. PREPARING ELECTROLYZER FOR
LONG STORAGE".
6. WATER FAILURE
In case of water failure, follow the instructions below:
1) Shut down the unit according to "5. SHUT DOWN".
2) Wait until water supply is resumed.
3) Check that the water supply valve is closed.
4) Open the drain valve.
5) Open the water supply line shut-off valve. Drain water until no rusty
water comes out.
6) Close the drain valve.
7) Start up the unit according to "4. START UP".
Water Outlet
Ends
Salt Water Tank
7. MAINTENANCE
1. Do not splash water directly onto the unit. It may cause short
circuit, electric shock, corrosion or failure.
2. To prevent electric shock, do not touch the attachment plug,
power switch (earth leakage circuit breaker), or other electri-
cal parts with damp hands.
1. To prevent electric shock or burn, always turn off the power
switch and unplug the unit before cleaning or inspecting the
unit.
2. Do not use combustible spray or place volatile and flam-
mable substances near the unit. They could catch fire from a
spark of a switch or the like.
To prevent damage to the painted or plastic surfaces, do not
use the following: thinner, benzine, alcohol, petroleum, soap
powder, polishing powder, alkaline cleaner, acid, and scouring
pad. When using a chemical cloth, follow the instructions of the
manufacturer.
[a] EXTERIOR
* The exterior is powder painted. Wipe it with warm water or a neutral
cleaner, if required. Use a damp cloth to wipe off any cleaner.
* The operation panel, salt water tank and water outlets are made of
plastic. Keep them away from impact or sharp edges.
[b] CLEANING FILTER AND SALT WATER TANK
1) Prepare a plastic bucket. Pull
out the cap, salt water hose and
filter from the salt water tank,
and put them into the bucket.
2) Wash the filter attached to the salt water hose with warm water,
and remove any dirt or dust to prevent the filter from clogging.
4
WARNING
CAUTION
IMPORTANT
Salt Water
Tank
Cap
Salt Water
Hose

Publicidad