Should the glass lid be broken or damaged, do not use the oven until the lid is replaced (Contact the
Assistence Centre).
SUBSTITUTION AND CLEANING OF COOLING FILTER
WARNING: Strictly adhere to the following procedure
in order to avoid electrocution or damage to people:
Disconnect the electrical connection of the oven
and leave it to cool.
Loosen the grid screws and substitute or clean
the filter.
Once this is done put everything back together.
IV. EXTRAORDINARY MAINTENANCE
It is advisable to have the appliance subjected to periodical checks (at least once per year) by a specialised
authorised technician.
Any maintenance, installation or repair work must be carried out by qualified authorised personnel by
contacting the Assistance Centre. Before carrying out any operation the appliance must be plugged out at the
mains, turn off the water mains taps and wait for it to cool down.
Before moving the appliance from position, check that the electricity and water connections (electric cables
water pipe and drainage) are correctly plugged out.
If the appliance is on wheels check that electric cables, pipes or anything else are not damaged while moving
it. Ensure the break is on. Avoid placing the device near heat (such as fryers etc.).
After carrying out the task and replacing the appliance in its initial position, check that the electric and water
are connected correctly.
V.

MAINTENANCE IN CASE OF BREAKAGE

If the appliance breaks, disconnect it from the mains and turn off water.
Before ringing Customer Service, check the chart below.
FAILURE
Oven light OFF
Non-uniform cooking by
the chamber
Non-uniform cooking by
the chamber
The oven is completely
OFF
The oven is completely
OFF
There is no water inflow
from the humidifier pipes
E n g l i s h
CAUSE
Loose lamp
Blown lamp
The fans no long invert
the direction of rotation
One of the fans not
operating
Failure of one of the
resistances
Supply voltage failure
Incorrect connection to
the power supply network
Safety thermostat
measure
Water inlet closed
Incorrect connection to
the water supply system
| 12
Correctly fit the lamp into the lamp holder
Replace the lamp (see ordinary maintenance)
Contact specialised technician for repair (Assistance Service ).
Contact specialised technician for repair (Assistance Service ).
Contact specialised technician for repair (Assistance Service ).
Restore power supply voltage
Check connection to the power supply network
Contact specialised technician for repair (Assistance Service ).
Open water inlet
Check connection to the water supply system
SOLUTION