EWR 2/EWR 2 Net

8.3 Main menu

8.4 Submenu 1 Parameter

The <1 Parameter> submenu is preset and can be changed as needed. Parameters can be changed only at
the "Setter" or "Service" authorization levels.
 4.2 Authorization levels/password on page EN-9
To open the main menu, press the <OK> button.
1
The following main menus are available:
To switch between the main menus, press the <◄ ►> arrow buttons.
2
To select a main menu, press the <OK> button.
3
To return to the main menu, press the <▲> arrow button or the <On/Bypass>
4
button.
Rate: 1 l/min, range: 2 to 23 l/min., regulating range: 2 to 30 l/min.
The solenoid valve in the wire feeder is open; the device regulates the gas
volume flow. Depending on the shunt signal, the device adds a value between 0
and 7 l/min linearly to the basic flow.
 15 Shunt types on page EN-27
Rate: 0.1 bar, range: 0.2 to 2.0 bar
The set-pressure can be set with the solenoid valve in the wire feeder closed
between the device outlet and solenoid valve. The set point to be set depends
on the back-pressure of the peripheral devices, for example, on the length/
radius of the cable assembly, amount of dirt and debris in the gas nozzle, etc.
The shielding gas used can be adjusted. There are ten memory locations. The
first five memory locations are preconfigured with conventional standard gases.
The other five memory locations can be configured as desired. The designation
of the open memory locations can be changed only with the service software.