8. CONTROL PANEL .
1 - DIGIT DISPLAY . In AUTOMATIC mode it shows instantaneous pressure (bar), instantaneous current com-
sumptions (A) and minimum speed (Hz).
2 - MANUAL START-STOP pushbutton. It allows to start and stop manually the pump.
3 - Pushbutton MENU for enter or quit the menu.
4 - With the ↑↓ pushbuttons we can increase or dicrease programming values showed in the screen.
5 - SET for saving programmed values. Every pulsation is succeeded by a new field of the CONFIGURATION
MENU. Whenever we want to quit the configuration sequence press MENU.
6 - Led lights:
• LINE green: Electric supply. Bright when it is connected.
• FAILURE red: Bright or flashing depending on type of failure.
• PUMP yellow: When it is bright means pump working. It is lit with the pump stopped or when the device
is not connected.
• AUTOMATIC green: it is bright in AUTOMATIC mode.
7 - Pushbutton ON/OFF: It allows to change from AUTOMATIC to MANUAL mode or vice versa.
9. START UP (plug&play).
Be sure that the pump is correctly primed.
Connect the device to the electric supply with the magnetothermic switch, all the led lights will flash
instantaneously for a second. Screen will show SP (Set Pressure) and then its default value 2,0 bar, both
displays are alternated in time periods of 1"/5". The device is plug&play following the next steps:
1. Set the nominal current of the pump following the instructions on chapter 10
2. Set the desired set pressure by mean of ↑↓
3. Press the push-button AUTO
The device will start to operate and led light AUTO ON/OFF will light. The screen will show the instanta-
neous pressure. Being in automatic mode and using the push-button SET we can change the display:
P: instantaneous pressure (bar).
Fr: instantaneous speed (Hz)
A: instantaneous current consumption (A)
ºC: instantaneous power module temperature (ºC)
8