Descargar Imprimir esta página

Installing Batteries - Emos P5611OT Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 191
ON
1
2
3
Selecting Temperature Differential
The temperature differential (hysteresis) is the difference in temperature required for
switching the system on and off. If, for example, you set the temperature in the heating
system to 20 °C and differential to 0.2 °C, the thermostat activates heating as soon
as room temperature drops to 19.8 °C and switches heating off when temperature
reaches 20.2 °C. Set the DIP switches (positions 1 and 2) depending on your choice of
temperature differential as indicated in the following figure.
1
2
ON
ON
OFF
ON
ON
OFF
OFF
OFF

Installing Batteries

The P5611OT thermostat is powered by two 1.5 V AA batteries.
1. Insert two AA batteries into the battery compartment located inside the control
unit. Make sure to observe correct polarity. Use 1.5 V alkaline batteries only; do
not use rechargeable 1.2 V batteries (due to their lower voltage). When you first
start the unit, the screen must show the time and room temperature.
2. If the screen shows different data, gently press the "RESET" button. To do this,
use a thin, straight object, such as an unfolded paper clip.
3. Replace the rear cover once the batteries are in place.
4. Before you turn on the main switch of the switching unit, press the "RESET" button
once. The thermostat is now ready for use.
Attention: After inserting batteries, the transmitter needs up to about 30 minutes to
stabilise parameters!
ON – heating
ON
OFF – air-conditioning
OFF
Span
0,1 °C
0,2 °C
0,5 °C
1,0 °C
9