Expansion Valve/Electric Drive Connection Diagram
Connected
device

PUTTING THE DEVICE INTO OPERATION

Pairing the Control Unit with the Switching Unit
Both thermostat units must be paired before first use.
Pairing enables transfer of information between the control unit and
the switching unit.
Setting is done via automated pairing (self-learning).
1. Remove the cover of the thermostat (transmitter) and insert 2×
1.5 V AAA batteries into the control unit (make sure polarity of
the batteries is correct). Only use alkaline batteries. Do not use
rechargeable batteries.
2. Correctly connect the switching unit to voltage supply, turn the main
switch to the position and long press (for at least 10 seconds) the
M/A button; a green diode will begin flashing.
3. Long press (for at least 3 seconds) the LEARN button on the ther-
mostat's (transmitter's) instrument panel.
The green diode on the switching unit will stop flashing and both units
are now paired.
If you want to change the pairing code of the two units, repeat the
entire pairing procedure from step 1 – the pairing code will be rewritten
automatically.
If the thermostat is not working properly, please check the polarity of
the batteries and whether they are sufficiently charged, or reset the
thermostat by removing and reinserting the batteries.
Testing Wireless Communication between the Units
1. Use the wheel to set a temperature a few degrees higher than the
current room temperature.
2. The red LED on the switching unit will light up.
3. If the LED does not light up, move the control unit closer to the
switching unit.