IMPORTANT PARTS OF YOUR CONCENTRATOR
Please take time to familiarize yourself with your DeVilbiss oxygen concentrator before operating
1
2
A
6
Front View (Figure A)
1.
Operating instructions (LED indicator panel)
2
Power Switch
| = ON
O = OFF
3
Flow meter knob
4
Flow meter
5.
Circuit breaker – resets the unit ater electrical overload shutdown
6.
Oxygen outlet tting – oxygen is dispersed through this port
7.
Normal Oxygen (green) light (see page 9)
8.
Low Oxygen (yellow) light (see page 9)
9.
Red Service Required (red) light – when illuminated contact your DeVilbiss
provider
10 Hour meter
Accessories
Transfiller Caddy
Bubble Humidifier
There are many types o humidiers, oxygen tubing and cannulas/masks that can be used with this device. Certain humidiers and accessories may impair the device's
perormance. A mask or any nasal cannula can be used with continuous fow delivery and may be sized according to your prescription as recommended by your homecare
provider who should also give you advice on the proper usage, maintenance and cleaning
WARNING
The accessories (nasal cannula, masks, oxygen tubing, humidiers, etc.) that supply oxygen to the patient must be equipped with a means that, in case o re,
stops the propagation o re through the accessory or the saety o the patient and others. A re activated fow-stop or thermal use device, i available, should be
used with the oxygen supply accessories. These types o fow-stop devices stop the fow o oxygen to the patient in the event o re. This means o re protection
should be located as close to the patient as practicable
WARNING
When using the Transller Caddy with a Transll device, always keep the system on a fat surace. Disassemble the system prior to moving.
NOTE – A maximum o 50 eet (15 meters) o crush-proo oxygen tubing, plus 7 eet (2.1 meters) o cannula, plus a bubble humidier is allowed between the concentrator
and the patient.
NOTE – Your healthcare provider should veriy the compatibility o the oxygen concentrator and all o the parts used to connect to the patient beore use.
A-525DS
8
7
9
3
4
5
10
B
15
16
11
14
12
13
Back View (Figure B)
11 Handgrip
12 Exhaust Vents
WARNING
When the device is used under extreme operating or single fault
conditions, the exhaust air near the exhaust vents on the bottom of
the unit may exceed 41˚. Keep exposed body parts, such as hands
and eet, a minimum o 46 inches (1.2 meters) away rom the exhaust
vents to avoid the risk of burns
13
Power cord and/or IEC power connector
14 Line cord strap
15. Filter Door with venting and compartment or optional gross particle lter
16. Auxiliary Oxygen Port (Serial numbers starting with R, N, or B): Your
concentrator is equipped with an auxiliary oxygen port that can be used to ll
oxygen cylinders with an FDA-cleared cylinder lling device that is designed
to use oxygen rom a concentrator to ll a cylinder. The port is only or use
with FDA-cleared lling devices with compatible oxygen input specications.
Reer to the cylinder lling device instruction guide or the oxygen input/
output specications, connection and operating instructions.
11
12
DeVilbiss 525DD-650
Salter Labs 7600 or equivalent
EN - 7