The P5616OT thermostat is designed for controlling heating and air-con-
ditioning systems.

Important

• Before the first use, make sure to carefully read the operating
manual for the thermostat, as well as the manual for the boiler or
air-conditioning equipment.
• Turn off power supply before installing the thermostat!
• Installation should be carried out by qualified personnel!
• During installation, observe the prescribed standards.

Technical specifications

Switched load: max. 230 V AC; 10 A for resistive load; 4 A for inductive
load
Temperature measurement: 0 °C to 40 °C with 0.1 °C resolution
accuracy ±1 °C at 20 °C
Temperature setting: 5 °C to 35 °C in 0.5 °C increments
Differential setting: 0.2 °C to 2 °C, in 0.1 °C increments
Power supply:
Control unit with display (transmitter): 2× 1.5 V type AA (LR6)
battery
Clock back-up power supply: 1× 3 V type CR2032 battery
Switching unit (receiver): 230 V AC
Unit interconnection: via 868 MHz radio signal, 25 mW e.r.p. max.
Transmitter unit range: up to 80 m in an open area
Dimensions and weight:
Control unit: 126 × 84 × 26 mm; 180 g
Switching unit: 86 × 86 × 36 mm; 146 g
Accessories: 2 screws, 2 wall plugs
Description of Control Elements (See Fig. 1)
1 – Home (return to home screen)
2 – Next (move to the next option within the current function)
3 – Adjust value setting
4 – Confirm (confirm function selection)
5 – Copy
6 – Holiday mode
7 – Battery compartment
8 – Time and date setting
9 – Select and edit programme (PROG)
10 – Anti-freeze mode (OFF)
4