3. INSTRUCTION FOR USE
Place before using lance and nozzle as in fig.2 and
make sure the nut is blocked.
3.1 SWITCHING ON
-
Make sure that the adjusting knobs on the torch (10
and 11) are closed.
-
Open the oxygen pressure reducer Micro (6) and the
gas valve 7/16 (open adjusting knobs).
-
Open the adjusting knob for gas on the torch (11).
-
Kindle using the special lighter (not supplied) paying
attention to keep the flame stucked to the solder-
ing nozzle. If the flame tends to come off the nozzle,
close a little the gas valve.
-
Open the adjusting knob for oxygen on the torch
(10) to obtain a sparkling flame.
-
Adjust the flame operating on the adjusting knobs to
have a dart with shape and dimensions like those of
picture 2.

3.2 SWITCHING OFF

-
Close first the gas valve on the cartridge (7).
-
Close the oxygen pressure reducer (6).
-
Let the flame estinguish till the hoses are empty.
-
Close the knobs of the torch (10 and 11).
i
PRECAUTIONS
-
Always use the kit with cylinder and cartridge
in vertical position or the gas liquid phase could
damage the hoses.
-
Do not work in a narrow place.
-
The CASTOLIN 2000 FLEX must be used in a well-
ventilated area, away from inflammable materi-
als or substances. Fire hazard!
-
Do not leave the CASTOLIN 2000 FLEX unattend-
ed when lit.
-
Do not put down the lit torch.
-
Work on a non-inflammable base.
-
During welding works wear goggles (15) and
gauntlets.
-
Do not use grease or oil on the parts in contact
with oxygen.
-
Do not wear clothes dirty with grease.
-
Attention! Avoid breathing welding fumes.
-
Replace immediatly the hoses with connections
(14a and 14b) in case of abrasions, deterioration
or other imperfections.
-
Avoid torsions and overheatings of the hoses
(14a and 14b).
-
During use, parts of the CASTOLIN 2000 FLEX can
reach high temperatures. After putting it out let it
become cool before putting it away.
-
It is dangerous to use damaged or incorrectly
functioning equipment.
-
In case of gas delivery problems, check if there is
gas in the cylinder and in the cartridge (4 and 5).
If so, the problem could be resolved by cleaning
the nozzle (see 5.4).
-
It is absolutely prohibited to make any mechani-
cal intervention on any component of the equip-
ment.
4. STORAGE
-
In case the CASTOLIN 2000 FLEX should not be used
for a long time or in case of transport by a motor ve-
hicle, unscrew the cylinders and the cartridges from
the respective pressure reducer and gas valve. This
will let you have the greatest guarantee to find the
content of the cylinder and of the cartridges intact
even much time later, avoiding the possibility of little
and almost imperceptible leaks, even though all their
valves are provided with guaranteed seal.
-
Put away the CASTOLIN 2000 FLEX in a protective
packaging (if possible in the original one) and keep it
in a cool, dry and well ventilated place.
i
PRECAUTIONS
For CASTOLIN 2000 FLEXS with cylinders and car-
tridges inserted :
-
Make the storage and the transport with the
cylinders and the cartridges in vertical position,
NEVER lying.
-
Protect from sunlight.
-
Do not expose to temperatures higher than 50°C.
-
Keep out of the reach of children.
-
Do not carry out maintenance or repairs, other
than the following.
-
Use only original spare parts and accessories.
-
Spare parts are available from your retailer.
-
In case of failures which cannot be repaired fol-
lowing these instructions, take your CASTOLIN
2000 FLEX back to the retailer.

5.1 GAS LEAKS

-
If your appliance leaks gas (gas smell) take it out-
doors immediatly to a well ventilated area, away
from inflammable sources where the seal can be
checked (see 5.2).
5.2 CHECKING THE SEAL
-
To check the seal of the CASTOLIN 2000 FLEX, work
outdoors and do not use a flame: use special detec-
tors or soapy water.
-
Spray the detector on the area to be checked.
-
Gas leaks are detected by the formation of bubbles
or foam.
5.3 CHANGING THE GASKET
-
Remove the worn gasket from its seat in oxygen
pres
sure reducer (6) and gas valve (7) with the
help of a little not sharp screwdriver.
-
Insert the new gasket, supplied in the little bag, into
the seat.
Messer Eutectic Castolin declines any responsibility in
case of accident caused by replacement of the seals of
the pressure reducer and of the gas valve. It is recom-
mended to do it by a specialist.

5.4 NOZZLE CLEANING

-
Unscrew the nozzle (13) with a wrench.
-
Clean the nozzle blowing into the hole with com-
pressed air.
-
Screw the nozzle (13) on the lance (12).
-
Check the seal (see 5.2).
i
PRECAUTIONS
-
Do not use needles or pins to clean the nozzle,
because any damage you may cause to the appli-
ance could make the CASTOLIN 2000 FLEX dan-
gerous.
-
If the blockage cannot be removed, substitute
the nozzle.
N.B. : Some of the details in the illustrations may dif-
fer from those of the appliance supplied. This company
reserves the right to modify the product without prior
warning.