NOTE
Damage to the connection cable due to tensile stress or crushing!
When laying, make sure that the connecting cable is not subjected to
tension or crushing in the joint areas.
Leave sufficient length when laying the cable!
4. Connect the connection cable (Pos. 4) to the connection cable of the
extraction hood (Pos. 3). To do this, shorten the connecting cable (Pos.
4), strip the insulation and connect it to the crimp connectors (Pos. 3.1)
with the same numbers.
5. Attach the rear end of the hose (Pos. 5) to the slewing ring. Use the
enclosed hose clamp (Pos. 5.1) for fixing.
6. Attach the other end of the extraction hose (Pos. 5) to the extraction
hood (Pos. 1). Use the enclosed hose clamp (Pos. 5.1) for fixing.
7. Fix the suction hose (Pos. 5) again with the hose clamps (Pos. 5.1).
1502759-03