BIR 01- _ _ _ _ -K15AL _-000S92
Inductive Rapid Positioning System
7
Configuration with the Balluff Engineering Tool (BET)
7.1
Balluff Engineering Tool (BET)
NOTICE
Interference in function
Configuration with the BET while the system is running
may result in malfunctions.
► Stop the system before performing the configuration.
The BIR can be quickly and easily configured on the PC
using the PC software BET.
The PC software and the relevant configuration
guide can be found online at www.balluff.com
on the product page.
7.2
Connect units
The units must be connected for configuration with the
BET.
PC (with BET)
IO-Link master
Power supply
Fig. 7-1:
Connection of units
► Connect BIR to the master via the adapter cable
(accessory).
► Optional: Also connect outputs to the control (PLC) via
the adapter cable.
► Connect PC (with BET) to the master.
16
english
7.3
Configuration options
Uncontrolled system movement
When starting up, if the BIR is part of a closed loop
system whose parameters have not yet been set, the
system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► The system must be taken out of operation before
configuration.
► The BIR may only be connected to the master box
for configuration.
► The master box must be removed after
configuration.
Prerequisites
BIR connected to IO-Link master and PC.
Software correctly installed.
BIR connected to the power supply.
Target on BIR.
BIR
PLC
(optional)
Functions of the outputs
Position in measuring range.
Status of the outputs
Status of the analog outputs is readable.
Freely configurable curve
Zero and end points can be taught-in (Teach-In).
The distance between zero point and end point must
be at least 10 mm.
The characteristic curve can be inverted.
The limits can be adjusted to the measuring range.
The error value can be set according to the limits.
DANGER
Further information can be found in the
configuration guide online at www.balluff.com
on the product page.