EN: Installation Sheet
Installation guidelines
Do not obstruct the detector field of view. Do not mount in
close proximity (see Figure 5). When using multiple detectors
ensure they are installed with 12 m distance between detectors
when facing or 2 m between detectors when used in parallel.
Keep beam away from vents, trees and shrubs and heat
sources (see Figure 1). For applications where the T-bracket is
used ensure the angle of the detector is pointing 2° away from
the building (Figure 4).
Detector placement and beam pattern
See Figures 2 to 7.
The detector uses microwave and infrared sensing to
determine motion detection. The optimum position of the
detector should be chosen to detect an intruder crossing the
beam pattern (Figure 2), and to avoid traffic from roads and
paths (Figure 3).
Mounting the unit
Secure the detector to a wall or solid fixture.
During installation, protect the electronics against water as
trapped moisture can affect or damage the unit. Unit supplied
has two mounting options (see below). Optional accessory
6930AMP-SB offers a third mounting option (see Figure 18)
and has ±45° pan and +15°, −45° tilt.
Basic installation, beam outward from surface
See Figures 2, 6, 10, 11, 12.
1.
Feed the cable through rear or side knock-outs and then
fix to the wall (Figure 10, items B and C).
Optional T-bracket installation, beam across surface
See Figures 3, 7, 13, 14, 15.
2.
Feed the cable through rear or side knock-outs (Figure 13,
item B) and out through cable access point (item C). Fix to
the wall and then secure the blanking plate onto the
unused side of the T-bracket (Figures 13, 14, 15).
Front assembly
See Figures 8, 9, 17.
3.
Feed cable through grommet. Clip middle section shown
into lower part of back section (Figure 9) push back until
flat to wall. Cut and wire the cable into the terminal blocks
(Figures 16, 17).
4.
Push the bottom of the front cover into clip on the middle
section and rotate back flat to the wall (Figure 9). Secure
by tightening the screw in access hole. Finally push fit
screw cover.
5.
To access the unit once installed first lever off the screw
cover (see Figure 8). Unscrew the screw in the access
hole. Next reverse steps shown in Figure 9 or to remove
from the wall use provided clip to lever off the wall
mounting (see Figure 8).
4 / 14
Settings
See Figure 17.
Walk Test
Set the LED Indication to Enabled, default (Figure 17). On
power up the LED will flash red and green alternately for
2 minutes. The detector will then indicate an alarm condition
with a red LED.
LED condition
Indication
Red and green
Power up cycle with
flashing alternately
LED Indication set
to Enable
Red flashing
Alarm Detection
Anti-Masking
Green on
detection
Specifications
Power input
Detection selectable range
Normally Closed Alarm
Normally Closed Masking
Normally Closed Tamper
Mounting height
Microwave frequency
Maximum beam pattern area
Walk Test
Cable (<200 m)
Operating temperature
Temperature compensation
Dimensions (H x W x D):
Detector
Boxed
T-Bracket
Weight
Packed weight
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
P/N 466-2676-ML • REV C • ISS 02APR21
To reset
Automatically 2 minutes
after start-up
Automatically flash for 1 s
with 5 s between detection
Automatically after masking
has been removed
12 V ±3 V at max. 40 mA
Note:
During installation the DC
supply fault current shall be limited
to a maximum of 1 A
3, 6, 9, 12 m
50 mA 24 VDC, Alarm time 10 s
50 mA 24 VDC, Alarm time 60 s
With 20 Ω impedance 50 mA
2.0 to 2.5 m
10.587 GHz
12 x 2.8 m
Using LED Indication
8 core 7/0.2 mm
−20 to +55°C
Digital
117 x 44 x 41 mm
125 x 63 x 53 mm
120 x 68 x 50 mm
97 g
134 g