4.3 - TANK CLEANING
If the drainage tank is dirty, wash it with cold or lukewarm water.
Switch the appliance off and disconnect the plug from the power socket.
Remove the tank (7).
Do not use detergent, scouring pads, chemically treated dust cloths, gasoline, ben-
zene, thinner or other solvents, as these can scratch and damage the tank and cause
water leakage.
5 - PRESERVATION OF THE APPLIANCE
If you do not intend to use the appliance for a particularly long period of time or if operations which could
produce a lot of dust must be performed, it is advised to store the appliance as follows:
• Switch the appliance off and disconnect the plug from the power socket.
• Empty any water remaining in the tank.
• Clean the air filter.
• Store in a fresh and dry place away from humidity.
6 - TECHNICAL DATA
Consult the rating plate applied to the product (Fig. 2) and the technical data listed below:
Rated Capacity
Power supply
Water tank capacity
Maximum Refrigerant Charge
Net weight
Maximum design pressure
Minimum room size
Dimensions
Fuse
SECCOPROF 30 P
30L / day (30°C, 80%RH)
AC 220-240V / 50Hz
8 L
R290 / 83g
25.5 kg
High Side: 3.2 MPa
Low Side: 1 MPa
4 m
(floor area)
2
312 x 453 x 635 mm
3.15 A
SECCOPROF 40 P
40L / day (30°C, 80%RH)
AC 220-240V / 50Hz
8 L
R290 / 96g
25.5 kg
High Side: 3.2 MPa
Low Side: 1 MPa
4 m
(floor area)
2
312 x 453 x 635 mm
3.15 A
EN - 17