1. Turn on the unit while holding down the "ZERO" button. After turning on the
unit and still holding the "ZERO" button, press the "UNIT" button three times.
The unit will go to the list of available functions to adjust.
2. To adjust the displayed parameter, press the "UNIT" button. The parameters
are adjusted using the "TARE" button.
3. To return to the main settings menu or skip a parameter and move to the next
one, press the "ZERO" button.
Available settings:
DISPLAYED
Corresponding
MESSAGES:
function
CAPu
Maximum load unit
CAP
Maximum load
CALU
Calibration unit
CAL
Calibration value
DIVS
Breakdown
ADC
ADC processing (in
bits)
Error messages:
Displayed
(SBS-PS-30; SBS-PS-1500
models)
message
Displayed
(SBS-PS-1800 model)
Function adjustment options
• kg
• lb
When the "UNIT" button is pressed, "0000"
will be displayed.
• Press the "HOLD" button to mark the desired
digit in the displayed number sequence.
• Press "TARE" to increment the marked digit.
• kg
• Ib
When the "UNIT" button is pressed, "0000"
will be displayed.
• Press the "HOLD" button to mark the desired
digit in the displayed number sequence.
• Press "TARE" to increment the marked digit.
• 0.5
• 1
• 2
• 18
• 21
message
Meaning
Batteries running low