USER GUIDE - VELTIUM LITE
TEMPORARY STATUS
Only in LITE Uno and
LITE Kubo chargers.
ERROR STATUS
Only in LITE Uno and
LITE Kubo chargers.
RESTARTING (Sweeping green + Initial
process will occur when instructed to do so from the charger SETTINGS screen in
the VELTIUM App, when the electric power is restored (or when the charger is
booted up for the first time), or following a firmware update. This process can take
20 to 30 seconds depending on the charger model.
UPDATING firmware (Flashing
process will occur when instructed to do so from the charger SETTINGS screen in
the VELTIUM App (or automatically in the LITE Uno or LITE Kubo chargers when
configured to do so). The charger will automatically restart at the end of the
process. This can take from 5 to 12 minutes depending on the charger model.
CONNECTING TO OR DISCONNECTING FROM A MOBILE DEVICE USING
BLUETOOTH (Flashing white):
INDICATOR when the charger is connected to/disconnected from a user's mobile
phone using Bluetooth.
CONNECTING TO A THREE-PHASE METER (Sweeping
searching for the Three-phase meter and is trying to connect to it. This process can
take up to 6 minutes.
LOST CONNECTION WITH THE THREE-PHASE METER (Flashing
charger has lost communication with the Three-phase Meter and is trying to restore
it.
WHAT TO DO:
Check that the two elements of the Three-phase Meter (Meter and Gateway)
have power input.
Check that the cables between the Three-phase Meter and the charger are not
damaged and that they are properly connected at both ends.
If the charger is connected to the Internet by Local Area Network, check that
the network router and other elements (switch, etc.) have power input and are
working properly.
If, having checked the above, the charger is still in the same status, go to the
SETTINGS screen of the charger and select the
Power Control
section. This allows you to continue using the charger without
this function. Next, contact the User Support service for specific help with this
issue.
TEMPORARY ERROR (Flashing
situation in the vehicle charging process and has stopped the charge for safety
reasons.
WHAT TO DO:
Disconnect the vehicle from the charger. This will make the error message
disappear and return the charger to the AVAILABLE status.
PERMANENT ERROR
(Red): The charger has detected an internal problem with the
charger and has stopped the charge for safety reasons.
WHAT TO DO:
Disconnect the vehicle from the charger and restart the charger.
If this status continues after restarting the charger, contact the User Support
service for specific help with this issue.
buzz): The charger is restarting. This
purple): The charger is updating the firmware. This
A flashing white light will appear on the LIGHT
NO
red): The charger has detected an anomalous
green): The charger is
yellow): The
option in the
Dynamic
EN
18

Publicidad

loading

Este manual también es adecuado para:

Lite unoLine kubo