USER GUIDE - VELTIUM LITE
Dynamic Power
Control
Communications
Only in LITE Uno and
LITE Kubo chargers
The
Dynamic Power Control
your home consumption at any given time, thereby ensuring that the total charge
(home and vehicle) never exceeds the contracted/available power supply.
To enable this function you must define the following:
Measuring device
No
Select
No
device installed or if you don't want the charger to regulate
the charge.
CURVE
Select
installations fitted and connected to the charger.
Only in LITE Uno and LITE Kubo chargers.
METER
Select
installations fitted and connected to the charger and follow the
instructions on the screen to ensure correct communication
between both elements.
Measurement device location
House
Select
circuit
a circuit that only measures home consumption, but not that
of the charger.
Select
General
in a circuit that measures the total consumption of both your
circuit
home and the charger.
Contracted power
Select the contracted or available power supply for your home; under no
circumstances must this supply be greater than the aggregate consumption of
your home and your electric vehicle.
Select the mode in which the charger will connect to the Internet to enable real-
time remote communication with the VELTIUM App:
WI-FI:
Press the
Connect
The VELTIUM App will search the charger for WI-FI networks visible to the
device. To do othis, the App will display a window with the message
Device for use with VELTIUM WF_XXXXXXXX
CONNECT.
Next, the VELTIUM App will display the list of visible WI-FI networks,
showing their signal strength and protection level. Select the WI-FI
network to which you want the charger to connect. If the network is
protected, type the password into the window displayed and press
CONNECT.
The VELTIUM App will automatically proceed with the necessary actions
to connect the charger to the selected WI-FI network. Once the process is
complete, you must press Finish.
feature regulates your vehicle charge according to
if you have no
Dynamic Power Control
CURVE
if you have this device for single-phase
METER
if you have this device for three-phase
House circuit
when the measuring device is located in
General circuit
when the measuring device is located
button and follow these steps:
measuring
where you must press
EN
24