Excluded Operating Environments:  
Certain  operating  environments  are  not  recommended  for  specific 
Maxeon  modules  and  are  excluded  from  the  Maxeon  Limited 
Warranty for these modules. 
No  Maxeon  module  should  be  mounted  at  a  site  where  it  may  be 
subject  to  direct  contact  with  salt  water,  or  other  aggressive 
environment. 
Modules  should  not  be  installed  near  flammable  liquids,  gases,  or 
locations with hazardous materials; or moving vehicules of any type. 
 
Performance Series Mounting Orientation 
Performance Series (P‐Series) modules are designed to be installed in 
landscape  orientation.  In  landscape  orientation,  P‐series  modules 
maintain higher power under row to row shading and edge soiling. 
 
5.2 Mounting Configurations 
 
Mounting  system  must  provide  a  flat  plane  for  the  modules  to  be 
mounted on and must not cause any twist or stress to be placed on 
the Module, even in case of thermal expension. 
 
Modules  may  be  mounted  at  any  angle  from  horizontal  to  vertical. 
Select  the  appropriate  orientation  to  maximize  sunlight  exposure.  
Maxeon  recommends  for  a  good  performance  of  the  system 
(reduction of soiling effect/water pooling) a minimum of 5˚ tilt angle. 
The cleaning frequency must be increased for modules installed with 
a very low angle. 
Commercial  modules  (96  &  128  cells)  frames  have  permanently 
attached stacking pins located a 20mm zone on the long side frame at 
388‐408 mm ("D" area in Figure 2). Mounting system hardware used 
with  commercial  modules  must  account  for  the  presence  of  these 
stacking pins (see Table 2).  
 
Specific  information  on  module  dimensions  and  the  location  of 
mounting and grounding holes is provided in Figures 2 and Table 2. 
 
In order to prevent water from entering the junction box, which could 
present a safety hazard, modules should not be mounted such that 
the front/top glass faces downward (e.g., on a tracking structure that 
positions  the  module  with  the  junction  box  facing  skyward  during 
sleep mode). 
 
We also want to remind that the watertightness is not ensured by the 
modules but by the mounting system and that drainage should be well 
designed for Modules. 
 
Clearance  between  the  module  frames  and  structure  or  ground  is 
required to prevent wiring damage and allows air to circulate behind 
the  module.  The  recommended  assembling  clearance  between 
modules  installed  on  any  mounting  system  is  a  minimum  of  5  mm 
distance. 
When installed on a roof, the module shall be mounted according to 
the local and regional building and fire safety regulations. In case the 
module is installed in a roof integrated PV‐System (BIPV), it shall be 
mounted over a watertight and fire‐resistant underlayment rated for 
such application 
 
Modules mounting systems should only be installed on building that 
have been formally considered for structural integrity, and confirmed 
to be capable of handling the additional weighted load of the Modules 
and mounting systems, by a certified building specialist or engineer. 
 
Mounting system supplier shall manage the galvanic corrosion which 
can  occur  between  the  aluminium  frame  of  the  Modules  and 
mounting system or grounding hardware if such devices is comprised 
of dissimilar metals.  
© June 2022 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice. 
Safety and Installation Instructions ‐ Document 001‐15497 Rev.X
The  module  is  only  certified  for  use  when  its  factory  frame  is  fully 
intact. Do not remove or alter the module frame. Creating additional 
mounting  holes  or  removing  the  stacking  pins  may  damage  the 
module  and  reduce  the  strength  of  the  frame,  therefore  are  not 
allowed.  Using  mounting  Clamps  or  clips  with  additional  grounding 
bolts  or  grounding  metal  sheets  could  be  in  compliance  with  this 
Safety  and  Installation  Instructions  manual  subject  to  conditions  of 
Section 4.1 
Modules may be mounted using the following methods only: 
 
Frame  Holes:  Secure  the  module  to  the  structure  using  the 
1)
factory  mounting  holes.    Four  M6  or  M8  stainless  steel  bolts, 
with  nuts,  washers,  and  lock  washers  are  recommended  per 
module.    Bolts  to  be  fasten  according  to  racking  supplier 
recommendations. Refer to Table 2 for the module dimensions 
and mounting hole locations. (Please refer to the arrows on the 
Table 2, E1&E2&E3&E4). 
 
Pressure Clamps or Clips: Mount the module with the opposite 
2)
clips  on  the  longer  and/or  shorter  side  of  the  frame  of  the 
module. The clips allowed location should be according to Table 
1.1.  Installers  should  ensure  the  clamps  are  of  sufficient 
strength  to  allow  for  the  maximum  design  pressure  of  the 
module.  Clips and clamps are not provided by Maxeon . Clamps 
must apply force collinear with the 'wall' of the module frame 
and not only to the top flange. Clamps shall not apply excessive 
force to the top frame, warp the top flange, or contact the glass‐ 
these  practices  void  the  module  warranty  and  risk  glass 
breakage. 
Figure 
illustrates locations for top 
frame  clamp  force.  Avoid 
clamping  within  50mm  of 
module  corners  to  reduce 
risk  of  frame  corner 
deflection 
and 
glass 
breakage.  When  clamping 
to  the  module  frame, 
torque should never exceed 15 N.m to reduce chances of frame 
deformation,  if  the  clamp  datasheets  show  a  specific  torque 
value which is lower than 15 Nm the installer should follow the 
torque value which ever is more stringent. A calibrated torque 
wrench must be used. Mounting systems should be evaluated 
for compatibility before installing specially when the system is 
not  using  Clamps  or  clips.  Please  contact  Maxeon  for  the 
approval  of  the  use  of  non‐standard  pressure  clamps  or  clips 
where torque values are higher than otherwise stated. 
 
End  Mount:  End  mounting  is  the  capture  mounting  of  the 
3)
length  of  the  module's  shorter  frames  with  clamps  on  each 
shorter  sides  of  the  frame.  Three  different  configurations  are 
possible: 1) with two mounting rails under the complete length 
of each shorter side of the Modules, (See Table 1.2), 2) with two 
mounting  rails  parallel  to  the  long  side  of  the  Modules  (See 
Table 1.2) and 3) without any mounting rail (See Table 1.2).  The 
end‐mounting rails and clips or clamps (identified as A
in  Table  1.1)  must  be  of  sufficient  strength  to  allow  for 
maximum  designed  test  pressure  of  the  module.  Verify  this 
capacity  with  the  mounting  system  of  vendor  before 
installation. 
Hybrid  Mount:  Combination  with  clamps  or  clips  located  on 
4)
longer or shorter sides of Modules are also possible, see Table 
1.2  for  allowed  configurations.  In  any  case,  four  clampings 
points are needed.  
 
MAXEON SOLAR TECHNOLOGIES, LTD. 
1a 
Force must not deform
top frame flange or
glass may break
Force has
to be
applied in
line with
frame
wall
Figure 1a: Clamp Force Locations
 
(1&2&3&4)

Publicidad

loading