Dimmer curves
linear
DMX value
SYSTEMINFORMATIONEN (System Info)
Starting from the main display, press the rotary-push encoder to enter the main menu. Turn the
left encoder (SELECT) to select the System Info menu item (note the selection arrow on the left)
and confirm by pressing the left encoder (ENTER). By turning the left encoder, you can now display
the desired information (see table).
System Info
Main CPU
Device firmware
LED Temp.
LED temperature display in degrees Celsius and Fahrenheit
Op. Hours
Total operating time in hours and minutes
Display
Display switch-off activated/deactivated
DMX-Fail
Operational status with DMX signal fault
Dim Curve
Dimmer curve
Dim Response Dimmer response
Red Shift.
Colour drift enabled/disabled
PWM
LED PWM frequency
Calibr.
Factory calibration / no adjustment / custom adjustment
Colour-Cal. R
Cross-mode adaptation of red
Colour-Cal. G
Cross-mode adaptation of green
Colour-Cal. B
Cross-mode adjustment of blue
Colour-Cal. W
Cross-mode adjustment of white
Autolock
Automatic locking of the controls activated/deactivated
Fan
Fan setting
MANUAL LOCKING FUNCTION
In addition to the ability to automatically protect the lamp from accidental and unauthorised oper-
ation (see "Settings" – "Auto-lock"), the controls can also be locked manually. Press and hold the
middle and right rotary-push encoders simultaneously for about 3 seconds. If an attempt is made
to change settings, "Locked!" will appear in the display, and changing the spotlight's settings via
the controls is no longer possible. After approx. 1 minute, the current operating mode is displayed
again. To release the lock, again press and hold the middle and right rotary-push encoders simul-
taneously for about 3 seconds. The display will show the previously displayed information.
exponential
DMX value
logarithmic
DMX value
S-curve
DMX value